1, LS790B portable SF6 Leak Detector overview of qualitative
For many professional leak detection requirements, the quick and accurate to identify
refrigerant leak is very critical. LS790B is the professional design of very effective
detection of all CFC, HFC, HCFC refrigerants and mixed refrigerants.
LS790B to maintain a strong multi-faceted applicability. Even today, the new refrigerant
such as R410A, R404, R407, R406 and so on. 10 adjustable sensitivity settings and sensor
circuit patented technology guaranteed to find any effective refrigerant leak of any size.
LS790B is light and easy to carry features. Expected to allow users to directly detect any
leakage in the area, not too far away or there is a limit to consider the place. It looks
to provide a comfortable grip capital, metal hose can be bent towards any direction.
LS790B leak detectors to advanced micro-processing circuit with user friendly features
combine to achieve the best leak detection. Design uses the most advanced sensors to detect
corona discharge all of the halogen gas with unmatched stability, reliability and
consistency. Instrument sensitivity setting of 10, more than 100 kinds of tones and 10
lights. LS790B leak even under severe background contamination can detect the smallest 7 g
/ year leakage. LS790B leak detectors to advanced micro-processing circuit with user
friendly features combine to achieve the best leak detection. Design uses the most advanced
sensors to detect corona discharge all of the halogen gas with unmatched stability,
reliability and consistency. Instrument sensitivity setting of 10, more than 100 kinds of
tones and 10 lights. LS790B leak even under severe background contamination can detect the
smallest 7 g / year leakage.
Features:
Variable sensitivity: only 10 range and sensitivity can detect all halogen gas leakage
instruments. At the lowest sensitivity settings, LS790B HFC-134a can detect the leakage
rate to 15 g / year; at the highest sensitivity settings, HFC-134a can detect the leakage
rate to 7 grams / year.
Remove
To remove the microprocessor in the memory, re-calibrated to the background conditions
Locking
Select Lock mode, measure and record the ion pump to detect the highest level, the highest
level when the issue of dual-tone signals and flash
Signal
And lock all the background pollution
Alarm options
Audible alarm, light alarm or sound and light alarm
Visible light
10 Mobile LED indicator changes direction relative amount of halogen leak, leakage
increased, LED from left to right shift in the locked state, there is leakage only when the
LED flash.
Low battery indicator
When the battery power is low, low battery indicator light was reduced to half brightness
18 "flexible probe
Freely bending metal tube probe
Saver
For 15 minutes, the instrument automatically shut down to extend battery life
Ultra-sensitive ion pump
No moving parts, valves or fans, extremely accurate air sucked into the sensor chamber. The
industry's only field replaceable ion pump sensor.
Detection Principle
DC negative corona discharge
Sound Alarm
Microcontroller 40HZ to 500HZ different tone, when the halogen gas leakage increases, the
increasing frequency tone
LED Alarm
Microprocessor-controlled LED indicator 10
Power supply
4 "AA" alkaline batteries
Battery Life
About 30 hours continuous use
Auto Close
Continuous use Automatic power off after 15 minutes
Operating Temperature
0 ℃ to 50 ℃
Procedures:
Note: In the air conditioning system, the test must be off the engine.
1, air-conditioning system or refrigeration system should have enough refrigerant gauge
pressure of at least 340kpa/50psi, while the system is turned off, the temperature is lower
than 15 ℃, pressure to reach this number of leak may not be detected.
2, careful not to stain the probe part of the metal hose, high concentration of refrigerant
in the environment, if the probe is particularly dirty or there is water, should take a
clean soft paper wipe or blow the air cleaner power plant. Taboo, do not use detergent or
solvent cleaning leak detectors, leak detectors with them to avoid adverse reflection of
unnecessary equipment damage.
3, detection of leaks throughout the system as follows: in all pipeline, hose and air
conditioning system parts to find traces of oil lubricants, damage and connected place,
with the leak probe to look carefully place each questionable, such as : All the joints,
hose and copper tube junction, each control parts of the maintenance points with a hat,
welding parts and so on.
4, testing should be continuous along the pipeline, so to ensure that no areas are missed.
If a leak is found, other parts of the system to continue testing to confirm whether there
are leaks.
5, and then test each region, the probe should be around the leak point, and not more than
25-50 mm / s movement, while the surface position detection rate does not exceed 5 mm / sec
slowly moving toward a possible leak probe region to find.
6, an obvious leak, such as is found, it is best to use high-pressure air to blow a leak.
If necessary, repeat the test in this place.
7, check the copper evaporator leaks, will need to open air and open to the highest, run 15
seconds. Turn off air conditioning and 10 minutes to reach all of the refrigerant piping.
Then the leak probe into protective cover or condensate discharge device within the
Department, to confirm that there is no water, such as leak detectors, alarms, leak
detection and refrigerant leak detection system maintenance points are essential. 8, to
comply with any refrigeration repair, damage and other cooling system maintenance, leak
detection and refrigerant leak detection system maintenance points are essential.
4, operation skills:
1, the wind environment: Do not test the wind environment leak, even if is a big leak can
not be detected, because the gas will leak out quickly into the atmosphere, so that you can
not be detected. If possible with lead foil to produce a gas mask on the joint or joints,
or to move without detection area to detect the wind environment.
2 sensitivity settings: MAC proposal to set the level of leak test 5-6, the best
sensitivity is set to 1, this allows variable output alarm. Visible light running within 10
light box, but not all of the instructions alarm. Note: Select high sensitivity to the
highest audible tone continuous tweet or all of the 10 consecutive light flashes, you need
to transferred to a lower sensitivity settings, try again.
3, selective filters: there is again a regional moisture leak detection leak detection
equipment will result in false alarms, when looking for leaks or other high humidity
evaporator capacity around the region when there has patented a selective dry filter. There
can be removed from the water caused the alarm.
5, leak confirmed:
If a leak is detected again after moving probe experiments, get the same leak alarm, you
can confirm the leak.
When to use PIN-POTNT key:
If there is a large area of the leak, the leak around the region will form a refrigerant
surrounding area, which is the source of leakage of refrigerant around the attack, so that
leakage is not easy to confirm, then will need to set the PIN-POINT key to solving these
problems . Click PIN-POINT button, start looking for leaks region, when the detected leak
will be automatically saved when the LS790B detect refrigerant concentration levels, the
highest concentration of the probe to find the level of refrigerant region, a bipolar alarm
began to alarm, allowing you to quickly find leaks source.
6, maintain:
LS790B air leak detector maintenance is relatively simple. Just a regular cleaning probe,
ion pump sensor and battery replacement.
1, low-voltage Tip: When you open the device, the LCD screen kept flashing the middle of
that battery power is low, you can replace the four AA batteries.
Note: Do not use rechargeable batteries.
2, replace the ion pump sensors: ion pump sensors require regular replacement, if the
instrument is indicated at the lowest sensitivity is not normal or when the false alarms,
requiring replacement of the ion pump sensor. Operation as follows:
First turn off the switch, to be replaced. This instrument is equipped with a new random
ion pump sensor.
3, with patented selective filters: the probe must be confirmed through the air is clean
pollution-free, non-blocking and is smooth. Remove the probe from the metal hose also
removed when the ion pump sensor (Note: must be shut down). Try to use low pressure air
blows off the dirty filter (do not try other means). If you still can not clean, we must
replace the new filter.
Contact Us
- Midwest Group
- Contact nameCherry Lin
- Phone86-189-59410778
- AddressNo. 1 3rd Street Shangdi Haidian Disctrict Beijing China 100085
- Self-Contained Sampling System - Michell Easidew sample system
- Fast Response SF82 Online Dew Point Hygrometer for Compressed Air Dryers
- Michell Easidew Advanced Online Dew Point Hygrometer
- Michell SF72 Rail Dew Point Transmitter
- Dew Point Hygrometer Michell Easidew Online Dew Point Meter
- Michell SF82 M12 Dew Point Transmitter for Compressed Air Dryers
- Michell SF52 Dew Point Transmitter for Industrial Dryers
- Michell SF82 Dew Point Transmitter for Compressed Air Dryers SF82 MiniDIN 43650 C
- Michell Dew Point Transmitter Michell Easidew 34 for Compressed Air Dryers
- Michell Easidew EA2-TX-100HD Moisture Transmitter for Safe and Hazardous Areas
- Vaisala Methane and Carbon Dioxide Multigas Probe MGP262
- Vaisala CO2 Probe GMP231 Carbon Dioxide Probe
- Vaisala CO2 Probe GMP343 Sensor
- Vaisala Indigo200 Transmitter With Best Price
- Vaisala Indigo80 Handheld Indicator
- Vaisala DMT143 Dew Point Transmitter
- Vaisala HMT370EX Intrinsically Safe Humidity and Temperature Transmitter
- Vaisala MMT310 Moisture and Temperature Meter
- Vaisala HMT310 Humidity and Temperature Transmitter
- Vaisala Humidity Module HMM100 For Environmental Chambers
- Vaisala CO2 Probe GMP251 GMP252 Carbon Dioxide Probe
- Vaisala Handheld Dewpoint Meter DM70
- Photochemical Reaction Instrument (LED) CEL-PCRD300-12
- 3D Printer Glove Box Probe Equipped High Accuracy Excellent Oxygen Transmitter Analyzer
Popular Searches
- Alcohol Tester
- alcohol breath tester
- alcohol tester breathalyzer
- alcohol detector
- breathalyser
- breath tester
- alcohol breathalyzer mouthpiece
- alcohol analyzer
- Breath Alcohol Tester
- Alcohol Content Tester
- Alcohol Breathalyzer Tester
- Alcohol Breathalyzer
- gas detector
- breathalyzer
- Gas Analyzer
- Oxygen Analyzer
Find Similar Products By Category
- Measurement & Analysis Instruments > Analyzers > Gas Analyzers
- Buy on GoldSupplier.com
- How to Buy
- Browse by Catagories
- Browse by Hot Regoins
- Private Sourcing Events
- Sell on GoldSupplier.com
- How to Sell
- Post Products
- Manage Products
- Manage Groups
- About
- About Us
- Link to Us
- Contact Us
- Sitemap
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
Cherry Lin
Welcome to my shop! Glad to serve you!Please send your question!
Your message has exceeded the limit.
Your message has exceeded the limit.
-
-
Your inquiry content must be between 20 to 5000 characters.Send Now.
-
Please input the mailbox.
-