Home > Products > Chemical Analyzer > GC102AF/GC112A/GC122 Lab Gas Chromatograph FID TCD FPD NPD Detector & Air Compressor Quality Choice
GC102AF/GC112A/GC122 Lab Gas Chromatograph FID TCD FPD NPD Detector & Air Compressor Quality Choice
- 50 Set / Sets per Month
- SHANGHAI
- T/T
Product Details
Place of Origin: | Zhejiang, China | Brand Name: | CHINCAN | Model Number: | GC102AF / GC112A / GC122 |
Power: | Electronic | Usage: | Auto Testing Machine |
Product Description
GC102AF Gas Chromatograph
As a new generation instrument, GC102AF Gas Chromatograph applies the computer reverse control technology and can conduct remote detection and fault diagnosis, equipped with a flame ionization detector (FID).
FEATURES:
1.PC control, user-friendly interface, and easy to operate.
2.Temperature control is of high accuracy (better than ±0.1℃). Heating speed is fast and overshoot temperature is small.
3.Self-diagnosis, power protection, oven over-temperature protection, and automatic ignition.
4.It can accurately display the temperature control settings, actual value, and FID amplifier sensitivity.
5.The single gas system and precise scale pneumatic control valve contribute to excellent reproducibility and stability and can perform analysis of packed column or capillary with wide diameter of 0.53mm.
6.Packed column: on-column injection, instantaneous vaporization injection, gas injection.
7.Open computer system and NJ2000 chromatography workstation can work together to process data.
8.Large capacity oven (300mm×280mm×270mm) facilitates the installation of packed column and capillary.
9.Built-in heating wire structure.
Technical specifications:
Temperature Control:
1. Temperature area: column oven, sampler, detector
2. Temperature range: 15℃ ~399℃ above room temperature (increment: 1℃)
3. Temperature accuracy: better than ±0.1℃ (measured at 200℃)
Flame Ionization Detector (FID):
1. Detection limit: Dt≤1×10-10g/s (octane and hexadecane)
2. Baseline drift: ≤2×10-12A/h
3. Linear range: ≥106
4. Max. limit temperature: 400℃
Others:
1. Voltage: 220V~±22V 50Hz±0.5Hz
2. Power: ≤1500W
3. Dimensions: 575mm(L)×480(W)×490mm(H)
4. Weight: 50kg
Optional:
NJ2000 chromatography workstation
GC112A Gas Chromatograph
Features:
1.High accuracy of temperature control (optimum: ± 0.05℃), high reliability and anti-interference.
2.Control and operating parameters (including for detectors) set up by the keyboard. Self-diagnosis system, power-fail protection, file storage and call, limited temperature setting. Accurate display of setting and actual value of temperature control of each path, bridge current of TCD, sensitivity of FID, retention and analysis time.
3.Four paths of independent control sections: column oven, sample injector, detector and thermal conductive pond.
4.5-ramp programmed temperature rising control. Auto-drop of temperature of column oven (auto-opening the door behind the oven) to a fast cooling.
5.Dual FID provided with options of GC112 A-TCD, GC 112 A-FPD and GC112A-NPD, gas sampling valve, transformation oven, absorber and pyrolysis absorber available for selection. Two detectors can be installed at the same time with high sensitivity. Short time to be stabilized and easy to clean and install nozzle.
6.Packed column and capillary column (0.53 large diameter or small diameter) can be installed easily including a complete set of split sampling connector and tailing connector to be installed free of charge.
7.Analysis can be conducted in packed or capillary column with multiple sampling methods.
8.Packed column: on-column sampling, instantaneous vaporized sampling and gas sampling.
9.Capillary column: split sampling and 0.53mm large diameter capillary direct sampling.
10.Construction of dual gas path, dual sample injector and dual packed column system can effectively avoid baseline undulation and drift in real time and facilitate programmed temperature rising analysis. Accurate and scaled type gas path control valves will provide a high repeatability and stability.
11.Advanced functions: auto ON/OFF temperature control system, permanent data storage, file storage and call and over-temperature protection.
12.Large volume column (300x280x270mm) can hold capillary column and dual packed column. Built-in heating filament structure is in favor of quartz capillary analysis.
13.A complete set of accessories including purifier, pressure-reducing valve, gas path tube, wrench and tools, injection needle and connectors of all kinds are provided free of charge and are ready to connect with supply-air system prepared by users.
SPECIFICATIONS
Temperature control
Control range | above room temperature 7℃- 400℃. (increment of 1℃) |
Control objects | column oven, detector, thermal conductive pond and sample injector |
Programmed temperature rising | 5 ramps |
Rate of programmed temperature rising | 0.1℃- 40℃/min (increment of 0.1℃) |
Thermostatic time | 0-655 min (increment of 1 min) |
FID
Sensitivity (minimum testability) | D≤5×10-11 g/s (sample: C16) |
Optimum testing result | D≤1×10-11 g/s |
Noise | ≤5×10-14 A |
Drift | ≤6×10-13 A/h |
Linear range | ≥106 |
TCD
Sensitivity | ≥2000mV.ml/mg |
Noise | ≥20μV |
Drift | ≤30μV |
Linear range | ≥104 |
FPD
Sensitivity (minimum testability) | ≤2×10-11 g (P)/s (sample: P in the parathion methyl) |
Optimum testing result: ≤3.8×10-12 g (P)/s. | |
Sensitivity (minimum testability) | ≤1×10-10 g (S)/s (sample: S in the parathion methyl) |
Optimum testing result: ≤2.7×10-11 g (S)/s | |
Linear range | ≥103 (sample P parathion) |
≥102 (sample S parathion) | |
Stability | ≤30μV/h |
Noise | ≤10μV |
Starting time | not greater than 2 hours |
NPD
Sensitivity (minimum testability) | Dt(N)≤5pg (N)/s |
Optimum testing result: 0.5ppm | |
Sensitivity (minimum testability) | Dt(P) ≤0.5pg (P)/s |
Optimum testing result: 0.2ppm | |
Drift | ≤8×10-13 A/h |
Noise | ≤4×10-13 A |
Linear range | ≥103 |
Max application temperature | 360℃ |
OPTIONAL ACCESSORIES
TCD
FPD
NPD
N2000 Software with I/O port
OVERALL DIMENSION & WEIGHT
Shipping package dimension: 990x630x690mm
Net Weight: 50kg
Gross Weight: 75kg
GC122 Gas Chromatograph
FEATURES
1.Dual FID detectors, optional GCl22-TCD, GCl22-ECD, GCl22-NPD, GCl22-FPD, converter, gas sample inlet valve, etc.
2.Dual packed columns, dual samplers and dual gas path system structure, which can effectively restrain baseline fluctuation and drift in real time, suitable for temperature programming analysis.
3.Can work with 3 types of detectors at the same time. With different detector combination in different application, the instrument can support detectors working in either cascade or paralleled connection.
4.Equipped with completed capillary analysis system and independent capillary split sampler, which includes diaphragm cleaning, split flow and auxiliary gas adjustment. It supports capillary split / split less sampler, cold on-column sampler, and 0.53mm large diameter capillary column direct sampler. It’s suitable for all kinds of capillary column of various diagrams, speculations, and lengths, and made of glass or flexible silicon glass.
5.The gas path of the instrument adopts high precision scale flow control valve, unloading valve and needle valve. It’s easy to adjust flow capability and has better reproducibility and stability.
6.The instrument supports following injection methods:
7.Packed column: on-column sample injection, instantaneous vaporizing sample injection, gas sample injection
8.Capillary column: split injection, split less injection, large diameter column direct injection
9.Newly developed computer aided temperature control system. It can manage the temperature control of six path heating areas at the same time, including column, ion chamber, thermal conductivity detector, capillary column sampler, packed column sampler auxiliary and standby, with high precision (less than ±0.1℃) and wide range (up to 400℃), and temperature overload and deviation is less than 2℃ or even lower.
10.The column has five-phase programmed temperature control, and the highest heating rate is up to 40℃/min.
11.The system has such functions as switch-off protection, temperature limit setup, temperature scanning,rapid automatic cooling, i.e. back opening door, and etc.
12.Open-end computer system can apply RS-232 interface and N-2000 chromatogram workstation to achieve single path communication control and data processing.
13.Large volume full lens stainless column (350mm×280mm×300mm) can support capillary column and dual packed columns at the same time. Inner-placed heating wire structure can facilitate silicon capillary column analysis.
PERFORMANCE INDICATORS:
Temperature control range: 7℃-400℃ of room
temperature (increment by 1℃)
Temperature control objects: column, ion chamber,
thermal conductivity, sampler A, sample B,
auxiliary (standby)
Temperature programming phase: five
Temperature programming rate: 0.1℃-40℃/
min(increment by 0.1℃)
Flame Ionization Detector (FID)
Sensitivity:M≤1×10-11g/s(sample: C16)
Optimal test result: M≤5×10-12g/s
Baseline noise: ≤5×10-14A
Baseline drift: ≤6×10-13A/h
linear range: ≥10E6
OTHERS
GC122 Special Purpose Detectors
GC122-TCD Thermal Conductivity Detector
Technology Indicators
Sensitivity: S >2500mV • ml/mg
(carrier gas H2)
(sample: n-Hexadecane)
baseline noise: ≤20 μV
linear range: ≥ 104
FEATURES
Applying rhenium tungsten filament, constant
current power supply, different magnifying circuit,
and mini-type conductivity
GC122-ECD Electron Capture Detector
Technology Indicators
Detection limit: Mt ≤2 × 10 -13g/s
( sample: n-hexane σ ,-666);
baseline noise: ≤ 10 μA
linear range: ≥103
Features
Ni-63 radioactive source applied, up to 350℃
working temperature, very high sensitivity to
halogen compounds.
GC122-NPD Nitrogen and Phosphorous Detector
Technology Indicators
Detection limit:
nitrogen: Mt ≤ 5×10 -11 g/S;
phosphorus: Mt ≤ 5 × 10-12 g/S
baseline nose : ≤ 4 × 1013A
linear range : ≥103
Features
High stability rubidium applied, suitable for nitrogen
phosphorus compound residue analysis.
GC122-FPD Flame Photometric Detector
Technology Indicators
Detection limit:
nitrogen: Mt≤ 2x10-11 g/S,
phosphor: Mt ≤1×10-10g/S
Baseline noise: ≤10 μV
Linear range: nitrogen≥103; sulphur≥102
Features
Dual flame structure, light-guide fiber signal transmission
line applied, greatly reducing the high
temperature affection on electric components,
suitable for phosphorus, phosphor trace analysis.
OPTIONAL ACCESSORIES:
TCD
FPD
NPD
N2000 Software with I/O port
OVERALL DIMENSION & WEIGHT:
Shipping package dimension: 1000x720x870mm
Net Weight: 100kg
Gross Weight: 120kg
Established in 2004, Hangzhou Chincan Trading Co., Ltd. is a foreign trading company authorized by Chinese State Department
of Foreign Economy & Trade and General Administration of Chinese Customs, which located in Hangzhou city, Zhejiang province, China.
We are a specialist company committed to exporting laboratory instruments, educational apparatus, medical & hospital equipments. With its superior performance, Chincan instruments are sold well throughout the Americas, Asia Pacific, the Middle East, Africa and Europe. With our excellent service, Chincan Trading has won a good reputation from the market.
Cooperative factories which qualified by Chincan come from many provinces and cities across China. All of them need to be ISO certified, Some products have CE.
Q: What after-sales service can be provided by CHINCAN ?
A: The after-sales service of CHINCAN is divided into two parts: technical support and maintenance.
Q: What about the technical support and maintenence?
A: Sometimes users will get some problems when they operate the instruments which are unfamiliar or first time use, users
can send us emails or call us about detailed information. We will provide users solution or operation video.For so many
years’ experience, our instruments works well during warranty period. If there any parts are broken during warranty period,
we would like to provide spare parts for free.
Q: How to solve the disputes between CHINCAN and customers during the after-sales maintenance?
A: We will be customer oriented,and make concessions in some principles , we will properly handle the disputes to maximize
customer's satisfaction.
Normally all CHINCAN products are supplied with a warranty of 12 Months from the date of shipment. This warranty is entirely dependent on the following conditions:
1.The following circumstance don't belong to the warranty policy which is Man-made damages caused by improper operations.
2.The instruments must be operated in accordance with our operating guidelines; serviced and maintained on a regular basis
in accordance with the terms specified in the relevant user manual.
3. Only approved spare parts should be used in the instruments which bought from CHINCAN and these should be changed on
a regular basis as specified in the relevant user manual. Details of the approved spare parts and accessories for each
instrument are shown in the user manual or alternatively this information can be obtained from CHINCAN.
Contact Us
- Hangzhou Chincan Trading Co., Ltd.
- Contact nameTom Fang
- Phone0086-571-87977725
- AddressNo.56 Liuhe Rd. Hangzhou,Zhejiang
- ASTM D4060 TABER Abrasion Tester Textile Abrasion Test Equipment TABER Wear Testing Machine
- Rotary Taber Abrasion Tester Taber Abrasion Resistance Test Machine Leather Wear Resistance Testing Equipment
- Most Popular UV Accelerated Aging Testing Machine Plastic Aging Test Equipment Climate Test Chamber
- Programmable UV Accelerated Aging Test Machine UVA Weathering Tester Rubber Aging Testing Equipment
- Programmable QVA Aging Test Machine Plastic Weathering Aging Tester Climatic Test Chamber
- JINGYAN Testing Instrument Simulated UV Weathering Tester UV Aging Test Chamber Environmental Test Chamber
- Air Permeability Tester
- Transportation Seismic Tester Simulated Transportation Shaker Table Mobile Phone Vibration Tester Mechanical Vibration Tester
- Random Vibration Tester Packaging Vibration Test Machine Simulate Transportation Vibration Testing Machine
- Professional Simulation Transport Shaking Tester Carton Vibration Table Automobile Vibration Testing Machine
- Photovoltaic inverter interface converter combined with 698 protocol converter to achieve information collection of inverter power generation and consumption
- Laboratory Testing Equipment Cardboard Boxes Single Arm Drop Test Machine Packaging Drop Impact Tester
- Most Popular Falling Drop Fatigue Testing Machine Carton Drop Tester Package Drop Test Equipment
- Universal Testing Machine Tape Peel Tester Adhesive Tapes Peel Strength Test Equipment
- Electric Tape Peeling Force Testing Machine PE Peel Tester 90 Degree Peel Strength Test Equipment
- ASTM D 4966 Non Woven Textile Fabric Abrasion Tester Martindale Pilling Test Machine
- ISO 15527 Textile Wear Resistance Testing Machine Martindale Test Equipment Floor Abrasion Tester
- ModBus-RTU infrared meter reader
- Lab Dry And Wet Abrasion Tester Paper Wear Resistance Test Machine Ink Rub Testing Equipment
- Paper Ink Rub Resistance Tester Ink Discoloration Testing Machine Rub Resistance Test Equipment
- DIN-53516 Abrasion Resistance Tester Universal Testing Machine DIN Leather Wear Resistant Test Equipment
- EN ISO 20344 Rubber Abrasion Test Machine DIN Abrasion Resistance Tester Friction Resistance Testing Equipment
- Rotary TABER Abrasion Tester Coating Abrasion Test Machine Wear Resistance Testing Machine
- Lab Leather Abrasion Resistance Testing Machine Fabric Abrasion Tester ASTM D4060 Wear Test Equipment
Popular Searches
Recommended Products
- ASTM D4060 TABER Abrasion Tester Textile Abrasion Test Equipment TABER Wear Testing Machine
- Rotary Taber Abrasion Tester Taber Abrasion Resistance Test Machine Leather Wear Resistance Testing Equipment
- Acrel three phase smart energy meter LED display 2DI2DO cut out 67*67mm AMC72-E4/KC Accuracy level 0.5
- Acrel Intelligent power collection and monitoring device AMC72L-E4/KC three phase LCD display 2DI2DO panel size 75*75mm
- Strong Mobility Portable Smart Lithium Battery Vertical Torque Wrench
- Nuclear Radiation Detector GM Geiger Counter, Sensitive Radiation Dosimeter Monitor Radioactive β Gamma X-ray CPM Level w/Alarm
- AITOP 5v3a6a10a20a30a50a60a100a Capacity Tester 8ch 5v100a Battery Capacity Tester battery charge discharge tester
- AITOP 32ch 64ch 5V60A30a20a10a Capacity Tester 8ch 5v100a Battery Capacity Tester battery charge discharge tester
- AITOP Capacity Tester 5V100A Battery Capacity Tester battery capacity charge discharge tester
- 100V100a60V100v20A/30A/50A/60A Professional battery charging and discharging aging cabinet
- 60V100a/100V100a Charging and discharge battery Discharging Aging Cabinet Aging Testing Instrument for Battery Pack
- Most Popular UV Accelerated Aging Testing Machine Plastic Aging Test Equipment Climate Test Chamber
Find Similar Products By Category
- Measurement & Analysis Instruments > Testing Equipment
- Buy on GoldSupplier.com
- How to Buy
- Browse by Catagories
- Browse by Hot Regoins
- Private Sourcing Events
- Sell on GoldSupplier.com
- How to Sell
- Post Products
- Manage Products
- Manage Groups
- About
- About Us
- Link to Us
- Contact Us
- Sitemap
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
Tom Fang
Welcome to my shop! Glad to serve you!Please send your question!
Your message has exceeded the limit.
Your message has exceeded the limit.
-
-
Your inquiry content must be between 20 to 5000 characters.Send Now.
-
Please input the mailbox.
-