Home > Products > Applications > AC DC multimeter calibration kit with class 0.5
AC DC multimeter calibration kit with class 0.5
- 100 Set / Sets per Month
- Beijing
- T/T Credit Card PayPal
Product Details
Place of Origin: | Beijing, China | Brand Name: | GFUVE | Model Number: | GF6018A |
Product Description
AC DC multimeter calibration kit with class 0.5
Application
It is suitable for power plant and substation work area of grid companies, make try department and the instrument classes, and national levels measuring and testing institutions, railway, petroleum, chemical industry and other large industrial and mining enterprises, scientific research units, etc.
Introduction
The device is according to verification regulation JJG124-2005 "ammeter, voltmeter, power meter and resistance meter calibration regulations of the requirements and design 0.05 magnitude AC and DC standard sources. The source of the signals of the DSP and 16 high-speed digital-to-analog converters can control of the sine wave, distortion wave source. The display users graphics standard 240 x 128 LCD monochrome screen, chart characters, showed clear. Circuit design perfect protection, reliable operation, easy to operate.
Main Functions and Features
1. The device consists of a single-phase AC voltage standard resource, current standard resource and DC voltage, current standard resource of standard resource.
2. Have calibration function, which can accord to the standard of external value, fixed standard resource output values.
3. The setting of the range for verification 1999 (9), 3999 (9) a display of the digital multimeter.
4. Manual and semi-auto inspection 0.2 % and below levels of digital multimeter, an analogue meter installation type digital instrument, including DC analog output of digital instrument.
5. To generate containing 2 ~ 31 harmonic wave distortion, the harmonic number, number, amplitude and phase of the harmonic wave to base wave all can be programmed control.
6. With RS232 interfaceand large capacity non-volatile memory, it can store 300 blocks inspected meter test data. Through the PC software, the PC controls this device automatic and manual inspection, and the results are processing and management.
Technical Data
AC output
Voltage range: 200 mV, 400 mV, 2 V, 4 V, 20 V, 100 V, 200 V, 500 V, 1000 V;
Current range : 20μA, 40μA, 200 μ A, 400 μ A, 2mA, 4mA, 20mA, 40mA, 0.2A ,0.5A, 2A, 5A, 10A, 20A;
Adjusting range 0 ~ 120% (1000 V voltage except);
Adjust fineness 5 x 10-5;
Voltage, current output capacity 20 VA;
Voltage, current adjustment for accuracy
± (0.03% RD + 0.02% FS);
Voltage, current output stability ≤0.01% / 60 s;
Voltage, current waveform distortion degree ≤0.3%;
Sine wave output frequency range (45-65) N Hz (N = 1, 2, 3,...... 31);
Sine wave frequency output fineness 0.001 N Hz (N = 1, 2, 3,...... 31);
Phase adjustment range 0 ~ 359.99 °;
Phase adjust fineness 0.01 °;
Harmonic output 2 ~ 31, range 0 ~ 20% (base wave ratings);
Harmonic phase fineness 0.01 ° N (N for harmonic frequency, N = 2 and 4,...... 31);
Output can also contains multiple harmonics, also can set base wave amplitude is 0, output power frequency than the sine wave.
DC output
Voltage range :200 mV, 400 mV, 2 V, 4 V, 20 V, 40 V, 100 V, 200 V, 400 V , 1000 V;
Current range: 20μA, 40μA, 200 μ A, 400 μ A, 2 mA, 4 mA, 20 mA, 40 mA, 0.2 A, 1 A, 2.5 A, 5 A, 10 A, 20 A;
Voltage, current, the adjusting range 0 ~ 120% (1000 V voltage except);
Voltage, current adjust fineness 5 x 10-5;
Voltage output capacity 20 W;
Current output capacity of 30 W;
Voltage, current adjustment for accuracy ± (0.03% RD + 0.02% FS);
Voltage, current output stability ≤ 0.01% / 60 s;
Voltage, current output ripple ≤1%.
Frequency output
Sine wave output range (using AC voltage, current output provide)
(45-65) N Hz (N = 1, 2, 3,...... 31);
Fineness 0.001 N Hz (N = 1, 2, 3,...... 31);
The setting accuracy 5 x 10-5;
Point 1 KHz square wave frequency output, 5 KHz, 10KHz, 50KHz, 100KHz, 200KHz, 1000KHz;
Square wave amplitude 4.5 V;
Electronic resistance box output
Quantity process
0 ~ 200 Ω, 200 ~ 400 Ω, 0 ~ 2 K Ω, 2 K Ω ~ 4 K Ω, 0 ~ 20 K Ω, 20 K Ω ~ 40 K Ω, 0 ~ 200 K Ω, 200 K Ω ~ 400 K Ω, 0 ~ 2 M Ω, 2 M Ω ~ 4 M Ω;
Fineness 0.025%;
Setting accuracy ± (0.12% RD + 0.08% FS).
Work power
Single-phase AC 220 V±10%, Frequency 50/60 Hz
Use of the environment
Temperature 0 °C~40 °C, Relative humidity ≤85% RH.
Volume and weight
440 mmx 450 mm x 160 mm, about 12 kg
Contact Us
- Beijing GFUVE Electronics Co., Ltd.
- Contact nameAndy Huang
- Phone86-10-85782698
- AddressBldg. 1-1006, Joy Mansion, No. 99, Chaoyang North Road
Applications | Current Transformer | Electrical Accessory | Electrical instruments |
Electrical Products | Handheld Terminal | New Products | Voltage Transformer |
- monopole steel tower
- power transmission line steel tower
- Electrical equipment frequency converter
- Vector Frequencyinverter
- Overhead power line fault indicator with Three color light display
- short circuit and earth fault indicator distribution system
- Current Temperature And Faults On-line Monitoring instrument
- how to reset overhead line earth fault indicator
- Electric Power Overhead type Cable Fault Indicator
- Simulated Failure Remote Controller for Overhead Line Fault Indicator
- Flag type Overhead type Short circuit &Ground Fault Indicator
- Installation adapter of Overhead Line Fault Indicator
- short circuit and earth fault passage indicator with good price
- overhead Line fault indicator for installation methods and tools
- Flag type Overhead type Short circuit &Ground Fault Indicator
- High Voltage Cable Fault Alarm
- overhead line fault sensor
- SNV-QS High Voltage Live Display Locking Device
- EKL4 Cable Short Circuit and Grounding Fault Indicator
- EKL4 Cable Short Circuit and Grounding Fault Indicator
- Remote Wireless Communication Terminal for overhead grounding and short circuit fault
- medium voltage overhead line fault current sensor and indicator
- Overhead type Short circuit & earth Fault Indicator manufacturer
- earth fault indicator distribution system
Popular Searches
Recommended Products
- SMA Female PCB Panel Edge Mount Connector Straight Solder RF Coaxial Adapter
- PM861AK02 Controller panel board card Can receive control signals
- PPD113 Inverter processor The reliability and stability of the system are improved
- 3BHB045647R0001 Input/output thyristor module Realize the control of high-power equipment with small power control
- 1S215UCVEH2AE Communication module Realize data transmission between devices
- IS215UCVEM08B Network communication module
- 5SHY3545L0014 Silicon control module Convert alternating current into controlled direct current
- 5SHY3545L0014 3BHE019719R0101 Silicon control module Convert alternating current into controlled direct current
- CP471-00 Remote I/O module Receive instructions from the autonomous controller
- AO2000 LS25 Central unit Analyzer module
- 3BHB045647R0003 Fieldbus optical interface Provides high-speed data transmission
- 1753-L32BBBM-8A Allen-Bradley Industrial controller
Find Similar Products By Category
- Electrical Equipment & Supplies > Power Distribution Equipment
- Buy on GoldSupplier.com
- How to Buy
- Browse by Catagories
- Browse by Hot Regoins
- Private Sourcing Events
- Sell on GoldSupplier.com
- How to Sell
- Post Products
- Manage Products
- Manage Groups
- About
- About Us
- Link to Us
- Contact Us
- Sitemap
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
Andy Huang
Welcome to my shop! Glad to serve you!Please send your question!
Your message has exceeded the limit.
Your message has exceeded the limit.
-
-
Your inquiry content must be between 20 to 5000 characters.Send Now.
-
Please input the mailbox.
-