Home > Products > DC/AC Power Inverter > Meanwell 1500W True Sine Wave DC-AC Inverter with Solar Charger 24v inverter/solar off grid inverter/ac drive inverter
Meanwell 1500W True Sine Wave DC-AC Inverter with Solar Charger 24v inverter/solar off grid inverter/ac drive inverter
- 900000 Piece / Pieces per Month
- Shanghai or Shenzhen
- T/T L/C D/P D/A Credit Card PayPal
- electric ac motor speed controller 480V 32A 18kw 3phase Input&3Phase Output AC frequency converter with 18 months warranty
- 45kw 380v vector control ac frequency converter 50hz 60hz motor frequency inverter 3 phase Power Frequency Converter for Pump
- EM15-G3 General used Vector control Frequency inverter(3 phase )
- EMHEATER soft starter
- EM GS2 7.5KW 220V 240V Motor Soft Starter for Submersible Pump deep well
- Inverter AB PowerFlex®7 Converter 22CD012N103 Inverter PowerFlex 400- 5.5 kW (7.5 HP) AC Drive
Product Details
Place of Origin: | Zhejiang, China | Brand Name: | Meanwell | Model Number: | TN-1500-124 |
Output Power: | Other, 1500W | Output Type: | Single | Size: | 420*220*88mm (L*W*H) |
Weight: | 6.85Kg | Input Voltage: | 24V | Output Voltage: | 110V |
Type: | DC/AC Inverters | Output Frequency: | 50/60Hz | Output Current: | 13.6A |
Product Description
MODEL | TN-1500-124 | |
OUTPUT | RATED POWER (Typ.) | 1500W |
MAXIMUM OUTPUT POWER(Typ.) | 1725W for 180 sec. / 1875W for 10 sec. / surge power 3000W for 30 cycles | |
AC VOLTAGE | Factory setting set at 110VAC | |
100 / 110 / 115 / 120VAC selectable by setting buttonS.W | ||
FREQUENCY | 60 ±0.1Hz 50/60Hz selectable by setting buttonS.W | |
WAVEFORM Note.2 | True sine wave (THD<3%) at rated input voltage | |
AC REGULATION (Typ.) | ±3.0% | |
TRANSFER TIME (Typ.) | 10ms inverter→ by pass | |
SAVING MODE (Typ.) | Default disabled. Load≤5W will be changed to standby mode | |
FRONT PANEL INDICATOR | Battery voltage level, output load level, saving mode, fault and operation status | |
INPUT
| BAT. VOLTAGE | 24V |
VOLTAGE RANGE (Typ.) Note. 3, 6 | 21~ 30VDC | |
DC CURRENT (Typ.) Note.5 | 75A | |
NO LOAD DISSIPATION | ≤18W at standby saving mode | |
OFF MODE CURRENT DRAW(Typ.) | ≤1mA | |
EFFICIENCY (Typ.) Note.2 | 89% | |
BATTERY TYPES | Open & sealed Lead Acid | |
BATTERY INPUT PROTECTION | FUSE | 30A*3 |
BAT. LOW ALARM | 22.5V±4% | |
BAT. LOW SHUTDOWN | 21V±4% | |
REVERSE POLARITY | By internal fuse open | |
OUTPUTPROTECTION | OVER TEMPERATURE | 82°C ± 5°C |
Protection type : Shut down o/p voltage, re-power on to recover ; by internal RTH3 detect on heatsink of power transistor | ||
OUTPUT SHORT | Protection type : Shut down o/p voltage, re-power on to recover | |
OVER LOAD (Typ.) | 105 ~ 115% load for 180 sec., 115% ~ 125% load for 10 sec. | |
Protection type : Shut down o/p voltage, re-power on to recover | ||
CIRCUIT BREAKER | 20A | |
GFCI PROCTECTION | Optional (Only type F) | |
ENVIRONMENT | WORKING TEMP. Note.1 | 0~+40°C at 100% load 60°C at 50% load |
WORKING HUMIDITY | 20%~90% RH non-condensing | |
STORAGE TEMP., HUMIDITY | -30~+70°C / -22~ +158 F, 10~95%RH | |
VIBRATION | 10 ~ 500Hz, 3G 10min./1cycle, 60min. each along X, Y, Z axes | |
SAFETY&EMC | SAFETY STANDARDS | UL458 (only for "GFCI" receptacle-Type F ) |
LVD | None | |
WITHSTAND VOLTAGE | Bat I/P - AC I/P:3.0KVAC Bat I/P - AC O/P:3.0KVAC AC O/P - FG:1.5KVAC | |
| EMC EMISSION | Compliance to FCC class A |
EMC IMMUNITY | None | |
AC CHARGER | CHARGE CURRENT (Typ.) | 2.7A |
CHARGE VOLTAGE | 28.5V±4% | |
SOLAR CHARGER | MAX OPEN CIRCUIT VOLTAGE | 45V |
CHARGE CURRENT (max.) | 30A | |
CHARGE VOLTAGE | 28.5V±4% | |
OTHERS | CONTROL WIRING | RJ11 -RS232 (Option) |
DIMENSION | 420*220*88mm (L*W*H) | |
PACKING | 6.85Kg; 2pcs/15.7Kg/1.61CUFT | |
NOTE | 1. Output derating capacity referenced by curve 1. 2. THD and Efficiency is tested by 1000W, linear load at 13V, 26V, 52V input voltage. 3. Input derating capacity referenced by curve 2. 4. All parameters not specified above are measured at rated load, 25°C of ambient temperature. 5. DC current is tested by 1500W, linear load at 13V, 26V, 52V input voltage. 6. The tolerance of each voltage value by models is:112/212 →±0.5V;124/224 →±1V;148/248 →±2V |
hing power supply dual output switching power
Contact Us
- Hangzhou Nuohan Electronics Co., Ltd.
- Contact nameRon Zhu
- Phone86-571-88687776
- AddressNo.5 Yufeng Road Xianlin industrial park Hangzhou,Zhejiang
- EMHEATER 250kw Three 3 phase 380V 400v 440V Input Motor Soft Starter for Submersible Pump Compressor
- 45kw 440v three phase star delta motor on line starter with bypass built in
- Economical Soft Starter 90kw Electric Motor Controller 3 Phase 400v 380v Motor Soft Starter 50Hz to 60Hz for motor protection
- Low Price 380V/480V 30KW Solid State Motor Starters Low Voltage Soft Starters with 60A Triple Output for Motor Protection
- MITSUBISHI HC-SF102BK (AS PICTURED) NSNP
- MITSUBISHI HC-SFS152 SERVO MOTOR
- original Mitsubishi MITSUBISHI HC202S NSNP
- AB 2711R-T7T
- AB 1492 1494 1497
- AB soft starter 150 153 156
- 480V 600KW 1200A 3 phase online working soft starter for AC motor pump mill motor air compressor no need bypass contactor
- 460V 480V 600KW 3 phase output power motor soft starter for Zimbabwe market AC motors
- 380V 500KW 1000A 3 phase input &output Soft starter for industrial pump acmotor air gas compressor fan crusher drawing machine
- 380V 500KW 1000A 3phase online working soft starter for AC motor pump mill motor air compressor no need bypass contactor
- 380v 500kw 3Phase input and output Frequency Converter Inverter speed drive Industrial ControL
- 480V 500KW 440V 3 phase Online Working Soft Starter VSD for AC motor pump mill motor air compressor no need bypass contactor
- 380V 500KW 1000A 3 phase input&output sine wave filter for variable frequency drive soft starters AC electric motor
- 380V 500KW Motor Controller Soft Starters for 3-phase Induction Motors Protection Relay
- TOP1 Hot Sales MPPT Solar Water Pump Inverter 3 Phase Triple Output DC/AC Inverter
- DC to AC 3-Phase 380V/220V MPPT Solar Water Pump Inverter/VFD with Variable Frequency and Triple Output Type
- 380V 450KW 900A 3 phase online working soft starter for AC motor pump fan mill motor air compressor no need bypass contactor
- 380V 600KW 800HP 3phase online working soft starter for AC motor pump motor compressor fan colloid mill built-in bypass
- China made Inverter AAD03020DKT01 for power plant
- Allen Bradley Soft Starter AB 150-F480NZD
Popular Searches
Recommended Products
- PFV1401 Electrical fire monitoring equipment Able to record the operation data of electrical system
- 81001-450-53-R Inverter module of the thyristor mainboard Progress in the level of technology
- 1C698CRE040 Digital input module card With electrical isolation function
- 5SHX2645L0002 Dc speed regulating medium pressure plate Can respond to control signals quickly and accurately
- 5SHY4045L0004 3BHB021400R0002 Unidirectional thyristor
- 5517B Laser interferometer The ability to measure optical changes with high accuracy
- 1C697CPX928 Single slot plc Provides rich interface options
- 5SHY3545L0010 3BHB013088R0001 Power module With high efficiency, high power density
- TRICONEX 3902AX Process monitoring redundant system Provides a variety of security control algorithms and function modules
- 1C697CPX935 Single-slot PLC CPU module Process a large number of input and output signals
- PPD113B01-10-150000 Programmable logic controller With high performance and reliability
- RET670 1MRK002816-AC Protection and control relay module Supports remote monitoring and control
Find Similar Products By Category
- Electrical Equipment & Supplies > Power Supplies > Inverters & Converters
- Buy on GoldSupplier.com
- How to Buy
- Browse by Catagories
- Browse by Hot Regoins
- Private Sourcing Events
- Sell on GoldSupplier.com
- How to Sell
- Post Products
- Manage Products
- Manage Groups
- About
- About Us
- Link to Us
- Contact Us
- Sitemap
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
Ron Zhu
Welcome to my shop! Glad to serve you!Please send your question!
Your message has exceeded the limit.
Your message has exceeded the limit.
-
-
Your inquiry content must be between 20 to 5000 characters.Send Now.
-
Please input the mailbox.
-