Home > Products > Tempering Valve > thermostatic valve
thermostatic valve
- 10000 Piece / Pieces per Month
- ningbo
- T/T Credit Card
Product Details
Pressure: | Vacuum | Material: | Other, Brass, Brass | Temperature of Media: | High Temperature |
Media: | Water | Port Size: | 3-1/2" | Place of Origin: | Zhejiang, China |
Model Number: | LYG-1550 | Brand Name: | XINXI | Application: | General |
Product Description
Type Solar Water Heater Parts
a.Working pressure:0.03-1Mpa b.Ideal working pressure:0.1-0.5Mpa c.Maximum working Temp.:Below 99C d.Cold water Temp. range:5-29C e.Hot water Temp. range:50-95C f.Outlet Temp. range:35-65C g.Adjustment Accuracy:+/- 2C h.Flow rate on 1 bar pressure drop:11.67L/min i.Connection:Inlets-M, Outlet-M Flow rate for pressure:
2.Materials of Construction a.Valve body:Brass with Ni-plated b.Shutter:PPO c.Spring:Stainless steel d.O-ring:EPDM
3.Features: a.Fail-safe on Hot or Cold Supply Failure b.Delivers Stable Mixed Water Temperature c.Extended Mix Temperature Range:35-45 C d.Idea for Domestic Water e.Tamper-Proof Cap 4.What is the thermostatic mixing valve? A Thermostatic Mixing Valve is a valve that blends hot water (stored at temperatures high enough to kill bacteria) with cold water to ensure constant, safe outlet temperatures preventing scalding. They shut-off rapidly in the event of a hot or cold supply failure to prevent scalding or thermal shock. TMVs accurately control water temperatures for bathing, showering and hand-washing. They maintain pre-set temperatures - even if water pressure varies when other appliances are used. TMVs can be fitted under baths and basins, be part of shower fittings, or as a feature of exposed hot and cold water mixers. 5.Usage of TMVs Point of use mixing for wash hand basins, bidets, baths and showers in hospitals, schools, sport and leisure facilities, prisons and other public buildings. 6.Installation Precaution: a.All installations should be carried out by a Licensed Professional. b.Install in accordance with markings on valve body. i.e. hot water inlet-marked H, cold water inlet-marked C. c.After temperature setting, if inlets temperature or pressure fluctuates, outlet temperature variation is within+/-2C. d.The external check valves at inlets prevent cross-flow of hot&cold water when inlets pressure is not the same. e.If the ratio between two inlets is too large, one flow-limiting valve should be fixed at the side of higher pressure. f.Prior to installation, provisions should be made to flush the piping of any debris or other foreign materials to ensure proper system operation. 7.How They Work? Upon use of tempered water, a thermostat in the mixing chamber of the valve senses the outlet temperature. The thermostat automatically positions a seat assembly which controls the flow of hot and cold water supplied to the mixing chamber. If the mixed outlet temperature increases, the thermostat will expand moving the seat assembly to allow the cold water inlet port to open more fully and at the same time restricting the hot water inlet port. Conversely, if the mixed outlet temperature decreases, the thermostat will contract moving the seat assembly to allow the hot water inlet port to open more fully and at the same time restricting the cold water inlet port. In both cases the mixed outlet water temperature is automatically and continually maintained at the preset temperature within the tolerances of the valve. In the event of a cold or hot water supply failure, the seat assembly moves to an extreme position shutting off the hot or cold inlet water port. A mechanical adjustment permits selection of the desired outlet water temperature within range of the valve
8.Installation Precaution: a.All installations should be carried out by a Licensed Professional. b.Install in accordance with markings on valve body. i.e. hot water inlet-marked H, cold water inlet-marked C c.After temperature setting, if inlets temperature or pressure fluctuates, outlet temperature variation is within+/-2C. d.The external check valves at inlets prevent cross-flow of hot&cold water when inlets pressure is not the same. e.If the ratio between two inlets is too large, one flow-limiting valve should be fixed at the side of higher pressure. f.Prior to installation, provisions should be made to flush the piping of any debris or other foreign materials to ensure proper system operation. 9.Relationsships between TMVs and Legionella: Legionella is the bacteria responsible for Legionnaires Disease, an acute bacterial infection of the lower respiratory tract. This bacterium was first identified in 1977 by the Centers for Disease Control as the cause of an outbreak of pneumonia that caused 34 deaths at a 1976 American Legion Convention in Philadelphia. Pontiac Fever is a less severe, non-pneumonia, flu-like disease that is associated with and likely caused by Legionella bacteria. Legionella is a fairly common water bacteria and has been found to exist widely in many surface water sources such as; lakes, rivers, streams and ponds. It can also be found in ground water sources and some soils. At the levels found in these naturally occurring sources it typically does not pose a threat to public health. When the bacterium enters a domestic water system It can find an ideal host environment of warm water temperatures (40-46Celsius degree), stagnant water areas (storage tanks and dead-end piping legs) and ample food sources (sediment, scale, deposits and biofilm). Under these conditions Legionella can rapidly colonize, forming higher concentrations that can pose the public health threat of Legionnaires Disease. There are many methods of controlling colonization of Legionella bacteria. However, a widely accepted and preferred method is to maintain the hot water system storage temperature continually at or above 60C. Unfortunately, the elevated temperature necessary to minimize the growth of and kill Legionella bacteria has the potential to cause serious thermal shock and scalding injuries |
Contact Us
- Taizhou Linyu Sanitaryware Co., Ltd.
- Contact nameJack xv
- Phone86-576-82741237
- AddressNo.58,Xusan Village,Pengjie,Luqiao Taizhou,Zhejiang
Kitchen faucet | New Products | Tempering Valve | Thermostat cartridge |
Thermostatic basin Faucet | Thermostatic bath mixer | Thermostatic shower faucet | Thermostatic Shower Rail |
- BOSCH supply X47 W-1.0 cast iron flanged oil seal plug valve
- Corrosion-resistant AST solenoid valve 3D01A011 for Aerospace
- High Performance solenoid coil 12vdc 300AA00309A for power station
- Bosch Supply X44 W-10 T Cast Copper Tee Flange Plug Valve All Copper Two Way Female Threaded Valve
- Rated PN32 1/2" to 1"for Gas Pipeline Brass Ball Valve
- Bosch Supply D373H-16C/P | Cast Steel Steel Stainless Steel Wafer Turbine Drive Butterfly Valve
- Bosch Supply Stainless Steel Free Float Steam Trap Cast Steel Flange Automatic Steam Trap CS41H-16P/C|
- X14W-10P Stainless Steel Tee Threaded Plug Valve
- Bosch Supply DQ44F Stainless Steel Low Temperature Tee Flange Extended Rod Ball Valve Floating Soft Seal Valve
- Metal Seat Rotary Ball Valve
- Top Entry Eccentric Semi Ball Valve
- Flanged Top Entry Ball Valve
- 3PC Floating Ball Valve
- Metal to Metal Trunnion Mounted Ball Valve
- Bosch Supply Float Type Steam Trap Cast Steel Welding Automatic Steam Trap
- Normally closed DN50 8240700.9101 BUSCHJOST NORGREN solenoid VALVES cylinder
- DN40 2/2 way 8240600.9101 BUSCHJOST NORGREN solenoid VALVES cylinder regulator
- International approvals 8240500.9101 BUSCHJOST NORGREN solenoid VALVES cylinder
- Damped operation 8240400.9101 BUSCHJOST NORGREN solenoid VALVES cylinder
- DN15 High flow rate 2/2 way 8240300.9101 BUSCHJOST NORGREN solenoid VALVES
- Stock High flow rate 8240100.9101 BUSCHJOST NORGREN solenoid VALVES
- DN40 Flange version valves remote pilot operated 8392600.8171 for norgren buschjost
- 2/2-way remote pilot operated 8392400.8171 norgren buschjost solenoid valve
- Electro-magnetic Pulse Valve service kit 8296600.8171 for norgren buschjost 1261402
Popular Searches
Recommended Products
- Caterpillar 9Y9895 9Y-9895 CAT Crankshaft Front Oil Seal For CAT Engine 3306
- CAT 7C4297 Caterpillar7C-4297 157.63mm Crankshaft Seal 3304 and 3306 engine
- BOSCH supply X47 W-1.0 cast iron flanged oil seal plug valve
- High pressure forged pipe fittings, equal diameter cross fittings, SW carbon steel cross fittings
- Corrosion-resistant AST solenoid valve 3D01A011 for Aerospace
- High-efficiency EH pump PVH074R01AA10A250000001001AB010A for steam turbine
- High Performance solenoid coil 12vdc 300AA00309A for power station
- Stainless steel butt welded flange high-pressure forged pipe fittings and fittings
- stainless steel welding nipple O.D. polished
- 313893 Multi-Row Bearing
- 313893 Multi-Row Bearing
- Rubber strip I100-BZM Generator QFS-300-2 for Turbine generator parts
Find Similar Products By Category
- Mechanical Parts & Fabrication Services > Valves
- Buy on GoldSupplier.com
- How to Buy
- Browse by Catagories
- Browse by Hot Regoins
- Private Sourcing Events
- Sell on GoldSupplier.com
- How to Sell
- Post Products
- Manage Products
- Manage Groups
- About
- About Us
- Link to Us
- Contact Us
- Sitemap
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
Jack xv
Welcome to my shop! Glad to serve you!Please send your question!
Your message has exceeded the limit.
Your message has exceeded the limit.
-
-
Your inquiry content must be between 20 to 5000 characters.Send Now.
-
Please input the mailbox.
-