Home > Products > Fire Alarm System > photoelectric beam detector
photoelectric beam detector
- 50000 Piece / Pieces per Month
- T/T
- 2023 China DC 48V Wired Smoke Fire Detector With Relay Output For Fire Alarm System
- 48V smoke detector 2023 China DC 48V Conventional Wired Optic Smoke Detector With Relay Output For Fire Alarm System
- OEM KF94/N95/KN95/surgical mask/KIDS face masks/adult face masks
- 2022 China DC 48V Conventional Wired Optic Smoke Detector With Relay Output For Fire Alarm System
- Siemens LME21.130C2 Control Box Siemens AG Brand New
- Siemens AG SQM48.497A9 Actuator LMV 5x System 20Nm IP54 Brand New
Product Details
Place of Origin: | Fujian, China | Brand Name: | GW | Model Number: | Independent Smoke Detector |
Product Description
Specifications
photoelectric beam detector1) Test by hand
2) Auto-reset
3) ASIC adopted
4) SMT design
photoelectric beam detector
Overview
My company succeed in developing a new generation of fire detectors, this detector using Infrared Radition scattering theory design, advanced SMT placement of the manufacturing process, perfect shielding measures, electromagnetic environment bad place to have the very good anti-interference ability. Also used the damp, anticorrosion, mildew prevent and other measures, in the high damp coastal areas have very good protection ability.
Performance and Characteristics
R Built-in infrared with high quality, containing sunlight filters, effectively filter environment light interference.
R Special optical labyrinth structure, fast response, good consistency.
R Advanced SMT paster technology,reliable shielding measures, the electromagnetic environment of bad places have very strong anti-interference ability.
R During normal working 5 seconds a bright lights and when fire the alarm indicator shows red.
R According to the new standard design..
The main technical parameters
Working voltage | Meet switch input device or monitoring module control terminals |
Monitor current | ≤70uA |
Alarm current | ≤20mA(DC24V resistance 1k) |
Wind speed | <5 m/s |
Protection area | 60~80m2,See |
Environmental conditions | Temperature :-10°C~+50°C Humidity :≤95%(40±2°C) |
Wire | Two lines |
Contour dimension
| Diameter 100mm Height 43.8mm |
Weight | About 82g |
beam
Contact Us
- Fujian Nanan City Guangwei Fire-Fighting Scie-Tech Co., Ltd.
- Contact nameCrystal Lin
- Phone0086-0595-86311863
- AddressLiantang South Road Ximei Town, Nan'an City Quanzhou,Fujian
Fire accessories | Fire Alarm System | Fire Cabinet | Fire Hose and Hose Reel |
Fire Hydrant | Fire nozzle&monitor | Fire Sprinkler | Foam system |
New Products | Wet alarm system |
- Siemens AG QRA4.U Brand New
- Siemens QRA10M.C Flame Detectors Brand New
- Siemens Flame Detectors QRA2 Brand New
- wholers sell KF94/N95/KN95/surgical mask/KIDS face masks/adult face masks/kids face masks
- wholers sell KF94/N95/KN95/surgical mask/KIDS face masks/adult face masks/kids face masks
- Honeywell BW GasAlertMicro 5 Detector M5-0W00-R-D-D-Y-C-00 With Good Price In Stock
- 2022 China DC 48V Wired Smoke Detector With Relay Output For Fire Alarm
- 2022 China DC 48V Wired Smoke Detector With Relay Output For Electronics Panel Security
- Fire Smoke Alarm Sensor Detector Smoke Alarm Smart Tester Home Family Guard Security
- ADPD188BI-ACEZRL OMO Integrated Optical Module 3.8mm x 5mm x 0.9mm with 1 blue LED,1 IR LED and 2 Photo diodes for Smoke Detector
- Analog Devices ADPD188BI-ACEZRL Integrated Optical Module complete photometric system for Smoke Detector
- TC Suction-type Smoke Detector Air Aspirating Smoke Sensor Fire Alarm Host 2Loops
- 4-wire Smoke Detector with Relay output Network Smoke Alarm NO/NC 24VDC
- Battery Powered Photoelectric Smoke Alarm Standalone Smoke Detector 9V for Home
- CO and Smoke Detector Carbon monoxide and Smoke Alarm sensor CO detector
- New Arrivel Mini Smoke Detector S832 With Relay Output 4 Wire Smoke Alarm Can Adsorption Metal Cabinet
- Conventional Smoke Detector Fire Alarm System Sensor Smoke Alarm DC24V Probe Detector
- Conventional Photoelectric Smoke& Heat Detector Multi Sensor Fire Alarm Heat Smoke Detector
- Intelligent Photoelectric Smoke Detector addressable Smoke Sensor Fire Alarm LPCB CE approved
- 4-wire smoke detector smoke sensor fire alarm with NO/NC DC9-35V
- Network Smoke Detector Fire Alarm 4 wired Smoke Sensor probe with Relay output DC9-28V
- 4 wire heat detector with relay output NO/NC network Temperature sensor Fire Alarm system DC9-28V
- CF6002 UV Flame Detector Ultraviolet Flame Alarm Sensor 4 wires Relay Output
- GST Beam Detector Conventional Reflective Beam Sensor Infrared Linear Smoke Detector C-9105R
Popular Searches
Recommended Products
- number plate recognition camera artificial intelligence camera
- AI fight Identification cameras artificial intelligence camera
- AI fight Identification cameras artificial intelligence camera
- AI personnel Sleep on sentry duty recognize camera artificial intelligence camera
- AI debris flow recognition camera artificial intelligence camera
- AI Drowning Recognition Camera artificial intelligence camera
- AI zoom large ball camera artificial intelligence camera
- AI vehicle occupancy recognition camera artificial intelligence camera
- AI Traffic Statistics Camera artificial intelligence camera
- AI fall recognition camera artificial intelligence camera
- AI ship recognition camera artificial intelligence camera
- AI electric vehicle recognition camera artificial intelligence camera
Find Similar Products By Category
- Security & Protection > Firefighting Supplies > Smoke Detector
- Buy on GoldSupplier.com
- How to Buy
- Browse by Catagories
- Browse by Hot Regoins
- Private Sourcing Events
- Sell on GoldSupplier.com
- How to Sell
- Post Products
- Manage Products
- Manage Groups
- About
- About Us
- Link to Us
- Contact Us
- Sitemap
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
Crystal Lin
Welcome to my shop! Glad to serve you!Please send your question!
Your message has exceeded the limit.
Your message has exceeded the limit.
-
-
Your inquiry content must be between 20 to 5000 characters.Send Now.
-
Please input the mailbox.
-