Home > Products > Gas sensor > HCN-B1 Hydrogen Cyanide Sensor (HCN Sensor)
HCN-B1 Hydrogen Cyanide Sensor (HCN Sensor)
- 1000 Piece / Pieces per Month
- HK
- T/T PayPal
- PH3-BE Phosphine Sensor (PH3 Sensor)
- NO2-AE High Concentration Nitrogen Dioxide Sensor (NO2 Sensor)
- RESP_IRR_20 C 15x15 Respiratory Irritant Sensor 20 ppm C Package 110-902
- TOCON_E2 SiC Based UV-Index Photodetector with Integrated Amplifier
- SG01L-B18 UVB-only SiC Based UV Photodiode
- LLC200D3SH Optomax Digital Series Liquid Level Sensors
Product Details
Brand Name: | Alphasense | Place of Origin: | United Kingdom | Model Number: | HCN-B1 |
Usage: | Gas Sensor | Theory: | Other, Electrochemical Gas Sensor | Output: | Analog Sensor |
Product Description
HCN-B1 Hydrogen Cyanide Sensor HCN Sensor Description
Alphasense is expanding its line of electrochemical toxic gas sensors to address industry-specific requirements, including emissions monitoring, process safety, environmental monitoring and VOCs.
Hydrogen Cyanide (HCN)
In manufacturing, the use of Styrene Acrylonitrile (SAN) for food packaging and other consumer products has increased the danger of HCN generated during fires. Alphasense has responded to this issue with HCN sensors with fast response and stable output.
Available in A, B and D series.
HCN-B1 Hydrogen Cyanide Sensor HCN Sensor PERFORMANCE | ||
Sensitivity | nA/ppm in 30ppm HCN | 80 to 140 |
Response time | t90 (s) from zero to 30ppm HCN | <120 |
Zero current | ppm equivalent in zero air | <±2.5 |
Resolution | RMS noise (ppm equivalent) | <0.05 |
Range | ppm HCN limit of performance warranty | 100 |
Linearity | ppm error at full scale, linear at zero, 40ppm HCN | 0 to 4 |
Overgas limit | maximum ppm for stable response to gas pulse | 200 |
HCN-B1 Hydrogen Cyanide Sensor HCN Sensor LIFETIME | ||
Zero drift | ppm equivalent change/year in lab air | nd |
Sensitivity drift | % change/year in lab air, monthly test | nd |
Operating life | months until 80% original signal (12 month warranted) | > 12 |
HCN-B1 Hydrogen Cyanide Sensor HCN Sensor ENVIRONMENTAL | ||
Sensitivity @ -20°C | % (output @ -20℃/output @ 20°C) @ 30ppm HCN | 70 to 95 |
Sensitivity @ 50°C | % (output @ 50℃/output @ 20°C) @ 30ppm HCN | 100 to 115 |
Zero @ -20°C | ppm equivalent change from 20°C | <0 to -2 |
Zero @ 50°C | ppm equivalent change from 20°C | <0 to 2 |
HCN-B1 Hydrogen Cyanide Sensor HCN Sensor CROSS SENSITIVITY | ||
H2S sensitivity | % measured gas @ 20ppm H2S | <400 |
NO2 sensitivity | % measured gas @ 10ppm NO2 | <-120 |
Cl2 sensitivity | % measured gas @ 10ppm Cl2 | <25 |
NO sensitivity | % measured gas @ 50ppm NO | <1 |
SO2 sensitivity | % measured gas @ 20ppm SO2 | <3 (transient) |
CO sensitivity | % measured gas @ 400ppm CO | <0.1 |
H2 sensitivity | % measured gas @ 400ppm H2 | <0.1 |
C2H4 sensitivity | % measured gas @ 80ppm C2H4 | <0.1 |
NH3 sensitivity | % measured gas @ 20ppm NH3 | <2 |
CO2 sensitivity | % measured gas @ 5% volume CO2 | <0.1 |
HCN-B1 Hydrogen Cyanide Sensor HCN Sensor KEY SPECIFICATIONS | ||
Temperature range | °C | -30 to 50 |
Pressure range | kPa | 80 to 120 |
Humidity range | % rh continuous | 15 to 90 |
Storage period | months @ 3 to 20℃ (stored in original container) | 6 |
Load resistor | Ω (recommended) | 10 to 33 |
Bias voltage | V | not required |
Weight | g | <6 |
Matched Transmitter board for HCN-B1 HCN Sensor
4-20mA Analogue Transmitter Board
• Factory calibration, custom-set for immediate use
• Wide operating voltage range
• Low RFI susceptibility
Alphasense 4-20 mA analogue transmitter boards provide a cost effective way for Original Equipment Manufacturers to engineer transmitter heads for fixed installation systems.
4-20mA Digital Transmitter Board
• Factory calibration, custom-set for immediate use
• Digital zero, sensitivity and temperature compensation
• Digital and 4-20mA output
• Biased or unbiased operation
• Calibration and range change
Contact Us
- Week technology ltd
- Contact nameCherry
- Phone86-0755-83289036-843
- Address16 Floor, Building #3, Zhongke Mansion, Gaoxin South Shenzhen,Guangdong
- MB1034 LV-ProxSonar-EZ3 High Performance Ultrasonic Rangefinder
- MTCS2601 Thermal Conductivity Sensor for Leak or Pressure Detection
- Clean CAP Plus Wireless Ultrasonic Fill-Level Sensor
- U14-REMOTE-232/485 ToughSonic REMOTE 14 Ultrasonic Water Level Sensor
- SONIC-ANEMO-DVC Ultrasonic Wind Speed Sensor
- NO2-B1 Nitrogen Dioxide Sensor (NO2 Sensor)
- NO-A4 Nitric Oxide Sensor (NO Sensor) 4-Electrode
- SG01M-18ISO90 Broadband SiC Based UV Photodiode A = 0.20 mm2
- SG01D-B18 UVB-only SiC Based UV Photodiode
- MB1220 XL-MaxSonar-EZ2 High Performance Ultrasonic Rangefinder
- Clean CAP Flex Wireless Ultrasonic Fill-Level Sensor
- CL2-B1 Chlorine Sensor (CL2 Sensor)
Popular Searches
Find Similar Products By Category
- Electronic Components & Supplies > Active Components > Sensors
- Buy on GoldSupplier.com
- How to Buy
- Browse by Catagories
- Browse by Hot Regoins
- Private Sourcing Events
- Sell on GoldSupplier.com
- How to Sell
- Post Products
- Manage Products
- Manage Groups
- About
- About Us
- Link to Us
- Contact Us
- Sitemap
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
Cherry
Welcome to my shop! Glad to serve you!Please send your question!
Your message has exceeded the limit.
Your message has exceeded the limit.
-
-
Your inquiry content must be between 20 to 5000 characters.Send Now.
-
Please input the mailbox.
-