Brand Name: | Alphasense | Place of Origin: | United Kingdom | Model Number: | HCL-B1 |
Usage: | Gas Sensor | Theory: | Other, Electrochemical Gas Sensor | Output: | Analog Sensor |
Product Description
HCL-B1 Hydrogen Chloride Sensor HCL Sensor Description
Alphasense is expanding its line of electrochemical toxic gas sensors to address industry-specific requirements, including emissions monitoring, process safety, environmental monitoring and VOCs.
Hydrogen Chloride (HCl)/Hydrogen Bromide (HBr)
The HCL sensor also detects Hydrogen Bromide (HBr). These HCL sensors are zero biased for easier use.
Available in A and B series.
HCL-B1 Hydrogen Chloride Sensor HCL Sensor PERFORMANCE | ||
Sensitivity | nA/ppm in 25ppm HCl | 150 to 250 |
Response time | t90 (s) from zero to 25ppm HCl | <200 |
Zero current | ppm equivalent in zero air | 0 to 3 |
Resolution | RMS noise (ppm equivalent) | <0.1 |
Range | ppm HCl limit of performance warranty | 100 |
Linearity | ppm error at full scale, linear at zero, 40ppm HCl | 0 to 6 |
Overgas limit | maximum ppm for stable response to gas pulse | 200 |
HCL-B1 Hydrogen Chloride Sensor HCL Sensor LIFETIME | ||
Zero drift | ppm equivalent change/year in lab air | nd |
Sensitivity drift | % change/year in lab air, monthly test | nd |
Operating life | months until 80% original signal (12 month warranted) | nd |
HCL-B1 Hydrogen Chloride Sensor HCL Sensor ENVIRONMENTAL | ||
Sensitivity @ 0°C | % (output @ 0°C/output @ 20°C) @ 25ppm HCl | 80 to 95 |
Sensitivity @ 50°C | % (output @ 50°C/output @ 20°C) @ 25ppm HCl | 100 to 108 |
Zero @ -20°C | ppm equivalent change from 20°C | <+0 to -1.0 |
Zero @ 50°C | ppm equivalent change from 20°C | <+0.5 to +2.5 |
HCL-B1 Hydrogen Chloride Sensor HCL Sensor CROSS SENSITIVITY | ||
H2S sensitivity | % measured gas @ ppm H2S | <280 |
NO2 sensitivity | % measured gas @ ppm NO2 | <-150 |
Cl2 sensitivity | % measured gas @ ppm Cl2 | <-100 |
NO sensitivity | % measured gas @ ppm NO | <2 |
SO2 sensitivity | % measured gas @ ppm SO2 (transient peak) | <1 |
CO sensitivity | % measured gas @ ppm CO | <0.1 |
H2 sensitivity | % measured gas @ ppm H2 | <0.1 |
C2H4 sensitivity | % measured gas @ ppm C2H4 | <0.1 |
NH3 sensitivity | % measured gas @ ppm NH3 | <0.1 |
CO2 sensitivity | % measured gas @ 5% CO2 | <0.1 |
HCL-B1 Hydrogen Chloride Sensor HCL Sensor KEY SPECIFICATIONS | ||
Temperature range | °C | -30 to +50 |
Pressure range | kPa | 80 to 120 |
Humidity range | % rh continuous | 15 to 90 |
Storage period | months @ 3 to 20°C (stored in original container) | 6 |
Load resistor | Ω (recommended) | 10 to 33 |
Bias voltage | mV | not required |
Weight | g | <13 |
Matched Transmitter board for HCL-B1 HCL Sensor
4-20mA Analogue Transmitter Board
• Factory calibration, custom-set for immediate use
• Wide operating voltage range
• Low RFI susceptibility
Alphasense 4-20 mA analogue transmitter boards provide a cost effective way for Original Equipment Manufacturers to engineer transmitter heads for fixed installation systems.
4-20mA Digital Transmitter Board
• Factory calibration, custom-set for immediate use
• Digital zero, sensitivity and temperature compensation
• Digital and 4-20mA output
• Biased or unbiased operation
• Calibration and range change
Contact Us
- Week technology ltd
- Contact nameCherry
- Phone86-0755-83289036-843
- Address16 Floor, Building #3, Zhongke Mansion, Gaoxin South Shenzhen,Guangdong
- T/R55.5-15.5E279Z-L19-01 Piezo Ultrasonic Sensor
- AM2306 Digital Temperature and Humidity Sensor
- SG01L-5 Broadband SiC Based UV Photodiode A = 1.0 mm2
- MB7092 XL-MaxSonar-WRMA1 High Performance Ultrasonic Rangefinder
- P235 Remote Particle Counter
- NO-D4 Miniature Size Nitric Oxide Sensor (NO Sensor)
- PH3-A1 Electrochemical Phosphine Sensor (PH3 Sensor)
- AM2315 Digital Temperature and Humidity Sensor
- MB1210 XL-MaxSonar-EZ1 High Performance Ultrasonic Rangefinder
- SG01XL-5 Broadband SiC Based UV Photodiode A = 7.6 mm2
- MB1030 LV-MaxSonar-EZ3 High Performance Ultrasonic Rangefinder
- SG01S-A18 UVA-only SiC Based UV Photodiode A = 0.06 mm2
- GUVA-S12SC-3LWH3 UV Sensor Probe UV Power Monitoring of Sunlight
- O2-A3 Electrochemical Oxygen Sensor (O2 Sensor)
- PH3-B1 Electrochemical Phosphine Sensor (PH3 Sensor)
- NH3-A1 Electrochemical Ammonia Sensor (NH3 Sensor)
- MB1240 XL-MaxSonar-EZ4 High Performance Ultrasonic Rangefinder
- SG01S-B18 UVB-only SiC Based UV Photodiode
- O2-G1 Miniature Size Oxygen Sensor (O2 Sensor)
- O2-C2 Electrochemical Oxygen Sensor (O2 Sensor)
- NH3-B1 Electrochemical Ammonia Sensor (NH3 Sensor)
- FPI-HS/HE EED/HERO Fiber Optic Signal Conditioner
- ULPSM-O3 968-005 Ultra-Low Power Analog Ozone (O3) Sensor Module
- SG01M-A18 UVA-only SiC Based UV Photodiode A = 0.20 mm2
Popular Searches
Find Similar Products By Category
- Electronic Components & Supplies > Active Components > Sensors
- Buy on GoldSupplier.com
- How to Buy
- Browse by Catagories
- Browse by Hot Regoins
- Private Sourcing Events
- Sell on GoldSupplier.com
- How to Sell
- Post Products
- Manage Products
- Manage Groups
- About
- About Us
- Link to Us
- Contact Us
- Sitemap
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
Cherry
Welcome to my shop! Glad to serve you!Please send your question!
Your message has exceeded the limit.
Your message has exceeded the limit.
-
-
Your inquiry content must be between 20 to 5000 characters.Send Now.
-
Please input the mailbox.
-