Home > Products > Smoke/Heat Detectors > 2-wire conventional Smoke Detector Fire proof Sensor Alarm DC9-28V
2-wire conventional Smoke Detector Fire proof Sensor Alarm DC9-28V
- 10000 Piece / Pieces per Month
- SHENZHEN
- T/T PayPal Cash Other
- 5 days
- Conventional Heat Detector Temperature Sensor Fire Alarm system
- 2 wire 9-28VDC Temperature Detector Heat Sensor for fire alarm system
- Mini 2 zones Fire Alarm Control Panel Security Host Master Panel FACP
- Conventional 4 zones Fire Alarm Control Panel Security Alarm control panel Fire Host
- 8 zones conventional Fire Fighting Panel Fire alarm control host FACP
- 16 zones Fire Proof Metal panel Alarm System control panel fire host
Product Details
Brand Name: | ZOANCO | Place of Origin: | China | Model Number: | YT102C |
Product Description
Traditional Smoke Detector 2-wire
1. GENERAL DESCRIPTION
The detectors are photo-electronic detector uses a state of-the-art optical sensing chamber. This detector is designed to provide open area protection and to be used with most conventional fire alarm panel.
Two LEDs on each detector provide local 360° visible alarm indication. They flash every six seconds indicating that power is applied and the detector is working properly. The LEDs latch on in alarm. LEDs will be off when a trouble condition exists indicating that the detector sensitivity is outside the listed limit. The alarm can be reset only by a momentary power interruption.
The detector that initiated the alarm condition will have its red LED and relays latched until reset by panel.
2. SPECIFICATIONS
Operating Voltage Range: 9 to 28 VDC Volts Non-polarized
Standby Current: ≤120µA@24VDC
Maximum Alarm Current (LED on): ≤20mA@24VDC (1K Ohm current-limiting resistance)
Operating Humidity Range: ≤95%RH(40°C±2°C) Relative Humidity, Non-condensing
Operating Temperature Range: -10°C to 50°C (14°F to 122°F)
Smoke Alarm Sensitivity: 1.06±.26%FT
Temperature Alarm Sensitivity: 57°C (135°F) A1R (only for with heat sensor)
Height: 48 mm installed in Base Diameter: 99 mm
3. INSTALLATION
NOTE: All wiring must conform to applicable local codes, ordinances, and regulations.
INSTALL THE DETECTOR BASE
1. Open area smoke or heat detectors are intended for mounting on a ceiling or a wall in accordance with the fire standard in your country.
2. Attach mounting base to ceiling or wall. The base of the detector can be mounted directly onto an electrical junction box such as an octagonal (75mm, 90mm or 100mm), a round (75mm), or a square (100mm) box without using any type of mechanical adapter.
3. Position all wires flat against terminals, and fasten the wires on the terminals, See Figure 1.
4. Terminals functions description:
Terminal 2: IN+( Zone Input+)
Terminal 5: IN- (Zone Input- )
Terminal 6: Remote Indicator+
Terminal 3: Remote Indicator-
Contact Us
- Shenzhen Zoanco Electronics Co.,Ltd.
- Contact nameJenny Ning
- Phone86-755-23015236
- Address4F, Building B1, XinHaoSheng High-Tech Park, YongHe Road, FuYong Town, Baoan District, Shenzhen, China Shenzhen,Guangdong
Smoke/Heat Detectors | Fire Alarm Control Panel | Conventional call point/button/bell | Beam Detector |
Gas Detector | Flame Detector |
- Conventional Fire Resistant Panel ABS fire alarm control panel in Red 4/8/16/24/32 zones optional
- Automatic Extinguisher Control Panel Fire Suppression Panel 4 zones for gas extinguishing system
- 24VDC Conventional Manual Call Point Fire Button fire alarm system devices
- conventional manual call point pull down plate button emergency fire button with key
- 9V Battery Cigarette Smoke Detector Smoke Alarm EN14604
- New Standalone Battery Powered Photoelectric Smoke detector smoke Alarm Fire Detector
- 4 zones extinguishant control panel for gas extinguishing system fire suppression panel
- AC/DC powered combustible gas detector kitchen gas leak detector sensor alarm
- GST Beam Detector Conventional Reflective Beam Sensor Infrared Linear Smoke Detector C-9105R
- CF6002 UV Flame Detector Ultraviolet Flame Alarm Sensor 4 wires Relay Output
- 4 wire heat detector with relay output NO/NC network Temperature sensor Fire Alarm system DC9-28V
- Network Smoke Detector Fire Alarm 4 wired Smoke Sensor probe with Relay output DC9-28V
- combination smoke and heat detector multi detector 4 wire smoke heat alarm sensor for fire alarm system
- 24VDC Conventional Manual Release Station for fire fighting panel
- Conventional Maintenance Switch MAINTENANCE panel key switch for fire fighting system
- Gas Release Lamp Indicator for fire fighting system
- 16zones Fire Alarm Repeater Panel display panel
- Explosion-proof UV flame Detector A705/UV fire detector Ultraviolet Sensor
- Dry contact Ex Double infrared flame detector relay output IR flame Alarm explosion-proof
- conventional sounder strobe fire protection audible and visual alarm DC24V
- Conventional Fire Alarm Bell Electric Bell DC24V for fire alarm system
- Ceiling mounted 4 wire gas detector with relay output DC24v powered LPG gas alarm sensor
- 220V AC Carbon Monoxide Gas Detector CO gas Alarm Sensor for all houses and kitchens
- 4-wire smoke detector smoke sensor fire alarm with NO/NC DC9-35V
Popular Searches
Find Similar Products By Category
- Security & Protection > Firefighting Supplies > Smoke Detector
- Buy on GoldSupplier.com
- How to Buy
- Browse by Catagories
- Browse by Hot Regoins
- Private Sourcing Events
- Sell on GoldSupplier.com
- How to Sell
- Post Products
- Manage Products
- Manage Groups
- About
- About Us
- Link to Us
- Contact Us
- Sitemap
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
Jenny Ning
Welcome to my shop! Glad to serve you!Please send your question!
Your message has exceeded the limit.
Your message has exceeded the limit.
-
-
Your inquiry content must be between 20 to 5000 characters.Send Now.
-
Please input the mailbox.
-