Home > Products > Gas sensor > CO/H2S-D2 Carbon Monoxide + Hydrogen Sulfide Sensor (CO + H2S Sensor)
CO/H2S-D2 Carbon Monoxide + Hydrogen Sulfide Sensor (CO + H2S Sensor)
- 1000 Piece / Pieces per Month
- HK
- T/T PayPal
- 7 days
- SG01L-5 Broadband SiC Based UV Photodiode A = 1.0 mm2
- NH3-B1 Electrochemical Ammonia Sensor (NH3 Sensor)
- FPI-HR High Resolution Fiber Optic Signal Conditioner
- G-series Combustible Gas Detectors with Analoge Output
- SD14 (SD10H) 10-Year Sealed Lithium Battery Power Smoke Alarm
- IRt/c.01HB Infrared Temperature Sensors
Product Details
Brand Name: | Alphasense | Place of Origin: | United Kingdom | Model Number: | CO/H2S-D2 |
Usage: | Gas Sensor | Theory: | Other, Electrochemical Gas Sensor | Output: | Analog Sensor |
Product Description
CO/H2S-D2 Miniature Size Carbon Monoxide + Hydrogen Sulfide Sensor Introduction
The world wide use of multigas, portable, personal safety monitors has grown since the 1970s to include an ever increasing number of industries. The one requirement in common to the majority of these instruments is the need to measure both Carbon Monoxide and Hydrogen Sulfide simultaneously.
Alphasense now offers a compact, dual gas sensor which allows designers to reduce significantly instrument size and cost. The D2 sensor provides a unique approach to the dual gas sensor in both its size and working electrode configuration. The use of a high capacity filter over the Carbon Monoxide working electrode eliminates Hydrogen Sulfide cross sensitivity to Carbon Monoxide.
Proven in the field over many years, these sensors perform well even under long term, challenging conditions.
D2 Specification Carbon Monoxide Channel
Carbon Monoxide Sensor PERFORMANCE | ||
Sensitivity | nA/ppm in 400ppm CO | 27 to 55 |
Response time | t90 (s) from zero to 400ppm CO | <25 |
Zero current | ppm equivalent in zero air | <± 6 |
Resolution | rms noise (ppm equivalent) | 1 |
Range | ppm CO limit of performance warranty | 1000 |
Linearity | ppm error at full scale, linear at zero and 400 ppm CO | <40 |
Overgas limit | maximum CO for stable response to gas pulse | 5000 |
Carbon Monoxide Sensor LIFETIME | ||
Zero drift | ppm equivalent change/year in lab air | <0.5 |
Sensitivity drift | % change/year in lab air, monthly test | <4 |
Operating life | months until 80% original signal (24 month warranted) | 24 |
Carbon Monoxide Sensor ENVIRONMENTAL | ||
Sensitivity @ -20℃ | % (output @ -20℃/output @ 20℃) @ 100ppm CO | 45 to 70 |
Sensitivity @ 50℃ | % (output @ 50℃/output @ 20℃) @ 100ppm CO | 105 to 125 |
Zero @ -20℃ | ppm equivalent change from 20℃ | -1 to 1 |
Zero @ 50℃ | ppm equivalent change from 20℃ | -1 to 4 |
Carbon Monoxide Sensor CROSS SENSITIVITY | ||
Filter Capacity | ppm-hours of Hydrogen Sulfide | 15,000 |
H2S sensitivity | % measured gas @ 20ppm H2S | <8 |
NO2 sensitivity | % measured gas @ 10ppm NO2 | <0.1 |
Cl2 sensitivity | % measured gas @ 10ppm Cl2 | <0.1 |
NO sensitivity | % measured gas @ 50ppm NO | <50 |
SO2 sensitivity | % measured gas @ 20ppm SO | <0.1 |
H2 sensitivity | % measured gas @ 400ppm H2 @ 20℃ | <55 |
C2H4 sensitivity | % measured gas @ 400ppm C2H4 | <200 |
NH3 sensitivity | % measured gas @ 20ppm NH3 | <0.1 |
Carbon Monoxide Sensor KEY SPECIFICATIONS | ||
Temperature range | ℃ | -30 to 50 |
Pressure range | kPa | 80 to 120 |
Humidity range | %rh continuous (see note below) | 15 to 90 |
Storage period | months @ 3 to 20℃ (stored in sealed pot) | 6 |
Load resistor | Ω (recommended) | 10 to 47 |
Weight | g | <2 |
D2 Specification Hydrogen Sulfide Channel
Hydrogen Sulfide Sensor PERFORMANCE | ||
Sensitivity | nA/ppm in 20ppm H2S | 90 to 160 |
Response time | t90 (s) from zero to 20ppm H2S @ 20℃ | <30 |
Zero current | ppm equivalent in zero air | <± 1 |
Resolution | rms noise (ppm equivalent) | <0.25 |
Range | ppm H2S limit of performance warranty | 100 |
Linearity | ppm error at full scale, linear at zero and 20ppm H2S | 0 to -9 |
Overgas limit | maximum ppm H2S for stable response to gas pulse | 400 |
Hydrogen Sulfide Sensor LIFETIME | ||
Zero drift | ppm equivalent change/year in lab air | <0.1 |
Sensitivity drift | % change/year in lab air, monthly test | <2 |
Operating life | months until 80% original signal (24 month warranted) | 24 |
Hydrogen Sulfide Sensor ENVIRONMENTAL | ||
Sensitivity @ -20℃ | % (output @ -20℃/output @ 20℃) @ 20ppm H2S | 75 to 90 |
Sensitivity @ 50℃ | % (output @ 50℃/output @ 20℃) @ 20ppm H2S | 103 to 112 |
Zero @ -20℃ | ppm equivalent change from 20℃ | -0.3 to 0.2 |
Zero @ 50℃ | ppm equivalent change from 20℃ | <±1 |
Hydrogen Sulfide Sensor CROSS SENSITIVITY | ||
NO2 sensitivity | % measured gas @ 10ppm NO2 | <-10 |
Cl2 sensitivity | % measured gas @ 10ppm Cl2 | <-10 |
NO sensitivity | % measured gas @ 50ppm NO | <10 |
SO2 sensitivity | % measured gas @ 20ppm SO2 | <10 |
CO sensitivity | % measured gas @400ppm CO | <2 |
H2 sensitivity | % measured gas @400ppm H2 | <1 |
C2H4 sensitivity | % measured gas @400ppm C2H4 | <1 |
NH3 sensitivity | % measured gas @ 20ppm NH3 | 0 |
Contact Us
- Shenzhen Isweek Ltd.
- Contact nameMs Rita yu
- Phone86-755-83289036
- Address16 Floor, Building #3, Zhongke Mansion, Gaoxin South 1st Rd, Hi-Tech Park, Nanshan Shenzhen,Guangdong
- Novagas2 Compact Infrared Gas Module - NG2 Series
- EE893 Digital NDIR CO2 Sensor Module for OEM Applications
- HCL-B1 Electrochemical Hydrogen Chloride Sensor (HCL Sensor)
- ETO-B1 Electrochemical Ethylene Oxide Sensor (ETO Sensor)
- CM9 Electrochemical Carbon Monoxide Sensor (CO Sensor)
- 850081DOK Dissolved Oxygen Meter Kit
- PSMU Series PM2.5/PM1.0 Particle Sensor
- CM8 Electrochemical Carbon Monoxide Sensor (CO Sensor)
- DO6400/DO7400 Series Submersible Galvanic Dissolved Oxygen Sensor
- 850039 Datalogging Conductivity/TDS Meter
- AM2322 Temperature and Humidity Sensor
- MMS-D010 ORAKEL Chlorine Sensor Water Quality Sensor
- CAEL-HT Series Multi-function Humidity and Temperature Transmitter
- LEPTON Single Element Uncooled VPD PbSe Detector
- TD40 Wireless Particle Monitor
- SF800-6 High Pressure Flow Meter
- SF800 Low Pressure Flow Meter
- EOPD-150-0-2.5 UV Photodiode
- HTG3513CH Voltage Output Temperature and Humidity Sensor
- CAEL-S16 Probe Humidity and Temperature Transmitter
- MMS-D016 ORAKEL COD/TOC Sensor Waste Analyser
- SH Thin-film Humidity Sensing Element Humidity Sensors
- 4S Rev. 2 CiTiceL Electrochemical Sulfur Dioxide Gas Sensor (SO2 Sensor)
- COH-A1 Carbon Monoxide/ Hydrogen Sulfide Sensor (CO/H2S Sensor)
Popular Searches
Find Similar Products By Category
- Electronic Components & Supplies > Active Components > Sensors
- Buy on GoldSupplier.com
- How to Buy
- Browse by Catagories
- Browse by Hot Regoins
- Private Sourcing Events
- Sell on GoldSupplier.com
- How to Sell
- Post Products
- Manage Products
- Manage Groups
- About
- About Us
- Link to Us
- Contact Us
- Sitemap
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
Ms Rita yu
Welcome to my shop! Glad to serve you!Please send your question!
Your message has exceeded the limit.
Your message has exceeded the limit.
-
-
Your inquiry content must be between 20 to 5000 characters.Send Now.
-
Please input the mailbox.
-