Home > Products > Fire Alarm Control Panel > Automatic Extinguisher Control Panel Fire Suppression Panel 4 zones for gas extinguishing system
Automatic Extinguisher Control Panel Fire Suppression Panel 4 zones for gas extinguishing system
- 100 Piece / Pieces per Month
- shenzhen
- T/T L/C D/P D/A Credit Card PayPal Cash Escrow Other
- 3 days
- 24VDC Conventional Manual Call Point Fire Button fire alarm system devices
- conventional manual call point pull down plate button emergency fire button with key
- 9V Battery Cigarette Smoke Detector Smoke Alarm EN14604
- New Standalone Battery Powered Photoelectric Smoke detector smoke Alarm Fire Detector
- 4 zones extinguishant control panel for gas extinguishing system fire suppression panel
- AC/DC powered combustible gas detector kitchen gas leak detector sensor alarm
Product Details
Brand Name: | zoanco | Place of Origin: | China | Model Number: | CM1004 |
Product Description
Automatic Extinguisher Control Panel Fire Suppression Panel 4 zones for gas extinguishing system
1. Introduction
The automatic extinguisher control panel is designed in accordance with European
standards EN54-2 and EN54-4 Fire Detection and Fire Alarm systems - Control and
Indicating Equipment and EN12094-1 Fixed firefighting systems - Components for
gas extinguishing systems - Part 1: Requirements and test methods for electrical
automatic control and delay devices.
The control equipment is a combined fire alarm control panel and extinguishing
system and has four detection zones, any or all of which are capable of contributing
to the extinguishant release decision.
Control panels have an integral, mains powered battery charger and power supply
designed in accordance with the requirements of EN54-4.
3. Technical specification
Table 1 - Electrical specifications
ITEM ELECTRICAL RATING COMMENT
Enclosure dimensions 353mm(L)×282mm(H)×101mm(W)
Net weight 3.3kg (Without batteries)
Mains supply input 200 to 240VAC 50/60 Hz 1A
Mains supply fuse 3 Amp ( F3A L250V) Replace only with similar type
Power supply rating 5 Amps @24VDC
Maximum ripple voltage ≤200 millivolts
Battery type Two 12 Volt sealed lead acid in series. 7Ah maximum
Maximum Battery Charging Current 0.98 Amps @ 26VDC
Current draw in mains normal condition 0.055 Amps
Current draw in mains fail condition 0.095 Amps With buzzer sounding
Current draw in second stage alarm 0.235Amps Two zones in fire(470 ohm in circuit)
Current draw in post discharge condition 0.350Amps solenoid outputs active
Maximum current draw from batteries 7Amps With main power disconnected
Sounder outputs(sounder & bell circuit) 26 to 28V DC Fused at 500mA with electronic fuse 1.2Amp total load over all circuits
Fault relay contact rating 2A /30VDC maximum for each Volt free changeover contact
Fire relay contact rating 2A /30VDC maximum for each Volt free changeover contact
First stage contact rating 2A /30VDC maximum for each Volt free changeover contact
Second stage contact rating 2A /30VDC maximum for each Volt free changeover contact
Extract contact rating 2A /30VDC maximum for each Volt free changeover contact
Zone quiescent current 4mA maximum
Terminal capacity 0.5mm2 to 2.5mm2 solid or stranded wire
Number of detectors per zone ≤30 PCS conventional detectors
Number of sounders per circuit Dependent on type and current consumption
Detection circuit end of line 4K7±5% 1/2 Watt resistor 3K to 5.6K 1/2W
Monitored input end of line 4K7±5% 1/2 Watt resistor 3K to 5.6K 1/2W
Sounder circuit end of line 10K±5% 1/2 Watt resistor 6.8K to 15K 1/2W
Extinguishant output end of line 10K±5% 1/2 Watt resistor 6.8K to 15K 1/2W
No. of detection circuits Four 21 to 26V DC
No. of sounder circuits Four 21 to 26V DC
Extinguishant release output 24V to 28V DC. Maximum load 2 Amp
Extinguishant release delay time Adjustable 0 to 75 seconds 5 second steps
SIL, AL, FLT, RST inputs Switched – min resistance 0 ohms, max 1k ohms
Detector alarm threshold 270 ohms to 1K ohms
Call point alarm threshold 150 ohms to 1K ohms
Short circuit threshold 0 ohms to 130 ohms
Status unit/Ancillary board connection Two wire RS485 connection with electronic fuse. Max. of 32 units-RS485 data cable
Contact Us
- Shenzhen Zoanco Electronics Co.,Ltd.
- Contact nameJenny Ning
- Phone86-755-23015236
- Address4F, Building B1, XinHaoSheng High-Tech Park, YongHe Road, FuYong Town, Baoan District, Shenzhen, China Shenzhen,Guangdong
Smoke/Heat Detectors | Fire Alarm Control Panel | Conventional call point/button/bell | Beam Detector |
Gas Detector | Flame Detector |
- GST Beam Detector Conventional Reflective Beam Sensor Infrared Linear Smoke Detector C-9105R
- CF6002 UV Flame Detector Ultraviolet Flame Alarm Sensor 4 wires Relay Output
- 4 wire heat detector with relay output NO/NC network Temperature sensor Fire Alarm system DC9-28V
- Network Smoke Detector Fire Alarm 4 wired Smoke Sensor probe with Relay output DC9-28V
- combination smoke and heat detector multi detector 4 wire smoke heat alarm sensor for fire alarm system
- 24VDC Conventional Manual Release Station for fire fighting panel
- Conventional Maintenance Switch MAINTENANCE panel key switch for fire fighting system
- Gas Release Lamp Indicator for fire fighting system
- 16zones Fire Alarm Repeater Panel display panel
- Explosion-proof UV flame Detector A705/UV fire detector Ultraviolet Sensor
- Dry contact Ex Double infrared flame detector relay output IR flame Alarm explosion-proof
- conventional sounder strobe fire protection audible and visual alarm DC24V
- Conventional Fire Alarm Bell Electric Bell DC24V for fire alarm system
- Ceiling mounted 4 wire gas detector with relay output DC24v powered LPG gas alarm sensor
- 220V AC Carbon Monoxide Gas Detector CO gas Alarm Sensor for all houses and kitchens
- 4-wire smoke detector smoke sensor fire alarm with NO/NC DC9-35V
- Intelligent Photoelectric Smoke Detector addressable Smoke Sensor Fire Alarm LPCB CE approved
- 24V Intelligent Rate of Rise & Fixed Temperature Heat Detector LPCB EN4 CE approved Addressable Heat Sensor
- Intelligent Fire Alarm Control Panel Addressable Fire Master Panel Security Host LPCB EN54 CE approved
- Analogue Addressable Manual Call Point Intelligent Alarm Button Fire Button LPCB EN54 CE approved
- Addressable sounder strobe Intelligent Sound Buzzer Fire Protection Audible and Visual Alarm LPCB EN54 CE approved
- Conventional Photoelectric Smoke& Heat Detector Multi Sensor Fire Alarm Heat Smoke Detector
- Conventional Smoke Detector Fire Alarm System Sensor Smoke Alarm DC24V Probe Detector
- Conventional Heat Detector 2 wired Temperature Sensor Fixed Temperature Alarm Heat Alarm
Popular Searches
Find Similar Products By Category
- Security & Protection > Firefighting Supplies > Fire Alarm Control Panel
- Buy on GoldSupplier.com
- How to Buy
- Browse by Catagories
- Browse by Hot Regoins
- Private Sourcing Events
- Sell on GoldSupplier.com
- How to Sell
- Post Products
- Manage Products
- Manage Groups
- About
- About Us
- Link to Us
- Contact Us
- Sitemap
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
Jenny Ning
Welcome to my shop! Glad to serve you!Please send your question!
Your message has exceeded the limit.
Your message has exceeded the limit.
-
-
Your inquiry content must be between 20 to 5000 characters.Send Now.
-
Please input the mailbox.
-