Home > Products > Environment monitoring instruments > RA-915S high frequency Zeeman effect mercury analyzer
RA-915S high frequency Zeeman effect mercury analyzer
- 20 Set / Sets per Month
- Shenzhen
- T/T Credit Card
- RL5000 type area x-Gamma radiation monitoring alarm
- TR-9300 continuous emission monitoring system for flue gas emissions
- TR-9300N ammonia escape analysis equipment
- HM-300A Multi-parameter Water Contaminant Tester
- HM-840 four parameter water quality analyser water quality detector
- HM-U800 ultraviolet multi-parameter water quality comprehensive detector
Product Details
Brand Name: | QDMH | Place of Origin: | Shaanxi, China | Model Number: | RA-915S |
Product Description
RA-915S high frequency Zeeman effect mercury analyzer
Introduction:
RA-915S uses a pyrolysis technique to heat release mercury from a solid sample to form mercury vapor, which is analyzed by absorption of a 254 nm resonance emission line by mercury atoms, background correction by Zeeman effect, and direct analysis of solids by pyrolysis. Mercury can be used for mercury detection of flue gas after enrichment by adsorption tube method.
Executive standard
HJ917-2017 "Measurement of gaseous mercury in fixed source of waste gas - Activated carbon adsorption / thermal cracking atomic absorption spectrophotometric method"
EPA Method 30B Determination of Gaseous Total Mercury in Coal Combustion Sources by Activated Carbon Adsorption Tube Method
Detection method:
The US EPA30B active adsorption tube flue gas detection method is a reference method for flue gas mercury emission detection. The method uses the adsorption tube to capture mercury in the flue gas for adsorption sampling, and then desorbs for concentration analysis, and can measure the total gaseous mercury concentration and the classified mercury concentration of the flue gas, ie (Hgo+ and Hg2+), the measurement result More accurate than the 30A method. This method is now widely used for the validation of routine online mercury mercury monitoring systems and has been used repeatedly for national and international research projects including the UNEP UN Mercury Project. The US EPA Mercury Monitoring Toolkit (MMT) is a Method 30 method that provides an efficient and convenient on-site solution package.
Flue gas sampling and detection systems mainly involve mercury adsorption sampling (EPA Method 30B Sorbent Trap), thermal analysis (EPA7473) and Zeeman effect atomic absorption spectroscopy (ZEEMAN-AAS). The system can realize all the monitoring items involved in the current pilot analysis of mercury emission testing of coal-fired power plants. Including: monitoring of mercury content such as waste gas, wastewater, solid waste, coal burning and fly ash.
Features:
1. It can directly analyze and detect mercury in samples such as food, soil, fuel, chemical products and biological tissues; it can be used for mercury detection of flue gas after adsorption by adsorption tube method;
2. The analyzer adopts high frequency Zeeman background subtraction technology, which is ultra-high selectivity and greatly reduces interference;
3. Wide dynamic detection range up to five orders of magnitude for analysis of ultra-high concentration samples;
4. Preset a variety of analysis modes, temperature real-time anti-control technology mode, reduce the interference of organic matter and chloride in the sample, no memory effect;
5. The analyzer does not need gold wire enrichment, catalytic tubes, carrier gas and other consumables, and the subsequent use and analysis cost is low;
6. Visualized mercury release interface, friendly user interface, easy to use and operate;
7. Built-in mercury saturated steam standard sample for calibration, ensuring high calibration stability;
8. Built-in air pump, automatic control of gas flow rate, no need for additional gas source;
9. The built-in power supply of the instrument can realize on-site portable field monitoring and directly detect the data directly;
10. Modular design for easy transportation and installation;
11. The expansion is strong, and the optional module meets the requirements of wastewater and air national standard detection.
12. Module composition
Flue gas sampling and detection system includes: flue gas mercury sampling system, activated carbon adsorption tube, mercury analysis and detection unit.
Analysis process
13. The analysis process is to use mercury special adsorption material (activated carbon, etc.) in the special adsorption tube, sample the flow rate in the chimney through the sampling probe, the mercury is enriched in the adsorption material, and the sampling flow rate and sampling time are recorded. The mercury analyzer was used to analyze the mercury content of the adsorbed material, and the mercury concentration in the flue gas was calculated by sampling flow rate and sampling time.
Technical Parameters
Detection limit: 0.05ppb
Injection quality: 10~500mg
Maximum concentration of sample detection: 200mg/Kg
Power supply: 198~242VAC, 50Hz
Detection unit: detection unit
Size: 470*210*110mm
Weight: 7.5Kg
Injection unit: injection unit
Power supply size: 380*260*130mm
Power weight: 10Kg
Optical unit and pyrolysis unit size: 350*350*120mm
Optical unit and pyrolysis unit weight: 7.0 Kg
Dear customer, We ,Xi’an Yima Opto-electrical Technology Com.,Ltd. is an integrated economic entity of R&D,manufacturing and trading with over 20 years of history . Our business scope covers various fields such as biochemical analysis,environmental protection,industrial testing, bioscience,medical apparatus and instruments,internet technology and some frontier science. Through a long-time development,we own a national resources system of various professional talents , abundant supply for various components &parts and special materials, full producing &processing equipments , strong Technological standardization and a complete quality assurance system. If you need OEM or ODM in manufacturing ,scientific research , market development and or you want to build your own brand in your country, it’s our honor to cooperate with you.In this way ,we have developed many products for our customers from the USA, Europe and South Africa and got good feedback on Alibaba We firmly believe that science and technology is no boundaries Our mission is to make every effort to contribute to all humanity. |
Contact Us
- Lixian Instrument Scientific Co., Ltd.
- P-1000 large flow bioaerosol sampler
- W-1000 large flow bioaerosol samplers
- CEMS-8000L type flue gas emission continuous monitoring system
- DL1 bio-aerosol real-time monitoring instrument
- DL bio-aerosol automatic identification instrument
- A300-1 Rapid Gene amplification Instrument
- DTC-4 DNA Thermal Cycler For PCR pcr machine
- TC - 96 - G/H (b) PCR Gene Amplification
- LineGene 96A Time PCR Detection System
- TL988 Real-time Quantitative PCR instrument with double channels
- DTC-4 PCR Gene Amplification Detection System
- ETC-811 PCR Instrument price of pcr instrument
Popular Searches
- Carbon Analyzers
- sulfur analyzer
- element analyzer
- infrared carbon sulfur analyzer
- Carbon Sulfur Analyzer
- Total Organic Carbon Analyzer
- Carbon Sulphur Analyzer
- Metal Analyzer
- bet surface area analyzer
- food safety testing equipment
- fat analyzer
- carbon analyzer
- diffraction
- Soil Tester
- Pesticide Residue Meter
- protein analyzer
Find Similar Products By Category
- Measurement & Analysis Instruments > Analyzers > Other Analysis Instruments
- Buy on GoldSupplier.com
- How to Buy
- Browse by Catagories
- Browse by Hot Regoins
- Private Sourcing Events
- Sell on GoldSupplier.com
- How to Sell
- Post Products
- Manage Products
- Manage Groups
- About
- About Us
- Link to Us
- Contact Us
- Sitemap
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
sales
Welcome to my shop! Glad to serve you!Please send your question!
Your message has exceeded the limit.
Your message has exceeded the limit.
-
-
Your inquiry content must be between 20 to 5000 characters.Send Now.
-
Please input the mailbox.
-