What is the unexcited voltage regulation of transformer? Shared by power transformers supplier.Let's take a look.
Non-field excitation changer is relative to on-load voltage regulating, have the load tap switch need to be considered when switching to stream of transformer, ensure continuous current, not affect the power grid, but no excitation regulating power refers to the state of voltage regulation, tap-changer stream. Don't need the transformer in the concrete operation, should have the power of the transformer and load switch are cut off. If there is a disconnecting switch on the high voltage side, it should also be turned on. And the bushing of the transformer are grounded, and then go to switch no load tap switch. Of course you are dry change, no tap switch, you can go to change tap.
When the voltage on the power side of the transformer fluctuates, it is necessary to adjust the number of turns on the primary side of the transformer, so as to keep the output voltage of the secondary side of the transformer as stable as possible. Generally, there are two kinds of voltage regulation: on-load voltage regulation (with load) and no-load voltage regulation (without load). As someone said in the past "no load voltage regulation" is not accurate, easy to be misunderstood, that can not carry the load, without cutting the original side of the supply voltage, voltage regulation. Therefore, the exact words should be called no excitation voltage regulation, that is, the transformer without excitation under the condition of voltage regulation (to cut off the original side of the transformer power supply, voltage regulation)...
That's all for the sharing,and we supply power transformers for sale, if you have any demand for our products,just feel free to contact us.
The company mainly produces: oil-immersed power transformers, dry-type transformers, box-type substation, high and low voltage switchgear assembly and a variety of special-type transformers. The hoisting, tooling and testing equipments are complete. Our company has passed the ISO9001-2015 international standard quality management system certification. All performance indicators of the products have reached the relevant national standards and international standards.
If you want to know more about the product, please click here.
More Products Please View Hifactory.
Contact Us
- Baoding Zhongyi Electrical Material Manufacturing Co.,Ltd.
- Contact nameJia Qiong
- Phone86-312-5926018
- AddressLianchi Baoding,Hebei
Oil Immersed Transformer | Dry Type Transformer | ZBW Type Prefabricated Substation | High and Low Voltage Switchgears |
news |
- Acrel leakage current transformer rated current 400-800A Applied to residual current signal collection AKH-0.66/L L-150
- Acrel measuring rated current 250-400A low voltage leakeage CT Residual current transformer AKH-0.66/L L-100
- Acrel Applied to residual current signal collection residual current transformer AKH-0.66/L L-200 rated current 800-1500A
- Acrel AKH-0.66/L L-80 rated current 100-250A Applied to residual current signal collection measurement current transformer
- Acrel leakage current transformer rated current 400-800A Applied to residual current signal collection AKH-0.66/L L-150
- Acrelrated current 800-1500A Applied to residual current signal collection residual current transformer AKH-0.66/L L-200
- Acrel AKH-0.66/L L-45 residual current transformer rated current 16-100A Applied to residual current signal collection
- Acrel smart AC current transformer BA20(II)-AI/V Can be widely used in industrial automation fields
- Acrel smart AC electrical transducer BA50(II)-AI/V Mainly detects the leakage current of the electrical system
- Acrel BA50L(II)-AI/V smart AC electrical current sensor Can be widely used in industrial automation fields out 1-5V/0-5V
- Acrel BA50L(II)-AI/V Can be widely used in industrial automation fields out 1-5V/0-5V smart AC electrical current sensor
- Made in China Three phase dry type transformer SG-100VA for thermal power plant
- Flyback transformer
- Lan transformer
- НЕФТЯНОЕ МЕСТОРОЖДЕНИЕ SHENGDONG SHENGLI газогенератор мощностью 500 кВт T12V190
- shengdong shengli oil field 500KW natural gas generator T12V190ZL
- B6190 G6190 200KW diesel engine used in ship boat spare parts
- B12V190ZL JINAN JICHAI DIESEL GENERATOR 1200-1600kw
- BH12V190ZL JINAN JICHAI DIESEL GENERATOR 1200-1600kw
- AL12V190ZL JINAN JICHAI DIESEL GENERATOR 1200-1600kw
- BL12V190ZL JINAN JICHAI DIESEL GENERATOR 1200-1600lw
- Acrel smart AC electrical current sensor BA50L(II)-AI/V Can be widely used in industrial automation fields out 1-5V/0-5V
- Acrel BA50L(II)-AI/I AC current sensor in AC0-(0.1-1)A out 4-20mA/0-20mA Real-time monitoring of AC current in the power grid
- Acrel smart AC electrical transducer BA50(II)-AI/V Mainly detects the leakage current of the electrical system
Popular Searches
- power transformer
- Distribution Service
- current transformer
- power transformers
- High Frequency Transformer
- Electrical Transformer
- energy saver device
- led transformers
- step up converter
- Ac Drive Converter
- Frequency Drive Converter
- electronic transformer
- Lighting Transformers
- toroidal transformer
- auto transformer
- voltage transformer
Find Similar Products By Category
- Electrical Equipment & Supplies > Transformers
- Buy on GoldSupplier.com
- How to Buy
- Browse by Catagories
- Browse by Hot Regoins
- Private Sourcing Events
- Sell on GoldSupplier.com
- How to Sell
- Post Products
- Manage Products
- Manage Groups
- About
- About Us
- Link to Us
- Contact Us
- Sitemap
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
Jia Qiong
Welcome to my shop! Glad to serve you!Please send your question!
Your message has exceeded the limit.
Your message has exceeded the limit.
-
-
Your inquiry content must be between 20 to 5000 characters.Send Now.
-
Please input the mailbox.
-