Home > Products > Conventional call point/button/bell > Conventional Fire Alarm Bell Electric Bell DC24V for fire alarm system
Conventional Fire Alarm Bell Electric Bell DC24V for fire alarm system
- USD $6.50 - $7.50 / Piece |Get Latest Price
- 10 Piece / Pieces
- 10000 Piece / Pieces per Month
- SHENZHEN
- T/T PayPal Other Cash
- 7 days
-
Ceiling mounted 4 wire gas detector with relay output DC24v powered LPG gas alarm sensor
-
220V AC Carbon Monoxide Gas Detector CO gas Alarm Sensor for all houses and kitchens
-
4-wire smoke detector smoke sensor fire alarm with NO/NC DC9-35V
-
Intelligent Photoelectric Smoke Detector addressable Smoke Sensor Fire Alarm LPCB CE approved
-
24V Intelligent Rate of Rise & Fixed Temperature Heat Detector LPCB EN4 CE approved Addressable Heat Sensor
-
Intelligent Fire Alarm Control Panel Addressable Fire Master Panel Security Host LPCB EN54 CE approved
Product Details
Brand Name: | ZOANCO | Place of Origin: | China | Model Number: | JL109 |
Packaging Details
Neutral packing
Product Description
General Description
The bell remains the most commonly used alarm for fire evacuation system, for wall applications, indoors.
They are designed to be used in 24 volt DC systems
Specifications
Voltage ranges: 20vdc to 28vdc (Nonpolarity)
Power and current consumption: 1W, 38ma@24vdc(maximum)
Number of standard: EN54-3
Sound level:80dB(A)@1M (minimum)
Service Use: Fire alarm, general signaling, burglar alarm
Environment type: Type A (indoor)
Input terminal Wire Gauge: 0.28 mm2 to 1.5 mm2
Operating Temp.: -10℃ to +55℃
Operating Humidity Range: 10% to 93% Relative Humidity ( Non-condensing)
Material of cover: Aluminum
Dimension: 150mm×50mm(D*H) (Without bracket)
Weight: Net Weight 342g, Gross Weight 395g
Wiring
The system designer must make sure that the total current drawn by the devices on the loop does not exceed the
current capability of the panel supply, and that the last device on the circuit is operated within its rated voltage.
When calculating the voltage available to the last device, it is necessary to consider the voltage drop due to the
resistance of the wire. The thicker the wire, the smaller the voltage drops. Wire resistance tables can be obtained from
electrical handbooks.
Contact Us
- Shenzhen Zoanco Electronics Co.,Ltd.
- ContactJenny Ning
- Phone86-755-23015236
- Address4F, Building B1, XinHaoSheng High-Tech Park, YongHe Road, FuYong Town, Baoan District, Shenzhen, China Shenzhen,Guangdong
Smoke/Heat Detectors | Fire Alarm Control Panel | Conventional call point/button/bell | Beam Detector |
Gas Detector | Flame Detector |
-
Analogue Addressable Manual Call Point Intelligent Alarm Button Fire Button LPCB EN54 CE approved
-
Addressable sounder strobe Intelligent Sound Buzzer Fire Protection Audible and Visual Alarm LPCB EN54 CE approved
-
Conventional Photoelectric Smoke& Heat Detector Multi Sensor Fire Alarm Heat Smoke Detector
-
Conventional Smoke Detector Fire Alarm System Sensor Smoke Alarm DC24V Probe Detector
-
Conventional Heat Detector 2 wired Temperature Sensor Fixed Temperature Alarm Heat Alarm
-
4 wired Ultraviolet Flame Detector with Relay Output UV Flame Alarm Sensor with Waterproof Shell
-
Conventional Horn Strobe Fire Protection Audible and visual Alarm Sounder Strobe Waterproof 24V
-
New Arrivel Mini Smoke Detector S832 With Relay Output 4 Wire Smoke Alarm Can Adsorption Metal Cabinet
-
Push in Pull Down Call Point Conventional Manual Call Point Fire Alarm Button DC24v for conventional fire alarm system
-
CO and Smoke Detector Carbon monoxide and Smoke Alarm sensor CO detector
-
Battery Powered Photoelectric Smoke Alarm Standalone Smoke Detector 9V for Home
-
4-wire Smoke Detector with Relay output Network Smoke Alarm NO/NC 24VDC
-
TC Suction-type Smoke Detector Air Aspirating Smoke Sensor Fire Alarm Host 2Loops
-
conventional sounder strobe fire protection audible and visual alarm DC24V
-
Dry contact Ex Double infrared flame detector relay output IR flame Alarm explosion-proof
-
Explosion-proof UV flame Detector A705/UV fire detector Ultraviolet Sensor
-
16zones Fire Alarm Repeater Panel display panel
-
Gas Release Lamp Indicator for fire fighting system
-
Conventional Maintenance Switch MAINTENANCE panel key switch for fire fighting system
-
24VDC Conventional Manual Release Station for fire fighting panel
-
combination smoke and heat detector multi detector 4 wire smoke heat alarm sensor for fire alarm system
-
Network Smoke Detector Fire Alarm 4 wired Smoke Sensor probe with Relay output DC9-28V
-
4 wire heat detector with relay output NO/NC network Temperature sensor Fire Alarm system DC9-28V
-
CF6002 UV Flame Detector Ultraviolet Flame Alarm Sensor 4 wires Relay Output
Popular Searches
- manual call point
- uv flame detector
- uv/ir flame detector
- emergency door release button
- alarm bell 220v
- alarm bells
- alarm ring bell
- automatic alarm bell
- alarms bells
- break glass fire alarm
- burglar alarm bell
- conventional manual call point
- electric alarm bell
- electric fire alarm bell
- emergency call point
- electronic fire bell
Find Similar Products By Category
- Security & Protection > Firefighting Supplies > Fire Alarm
- Hot Searches:
- fire alarm
- fire alarm bell
- electric bell