- Chongqing Enrich Engineering and Technology Co., Ltd
- China Manufacturer with main products:hydropower plant equipments ,electric power equipments ,power distribution equipments ,hydro turbine generator ,Industrial water filter&oil purifier ,Instrument transformer ,Power quality monitoring&improvement ,Reactor/Inductor ,Busduct ,Circuit breaker&Isolating switch&Load switch ,Filter press ,Slurry Pump
Home > Products > Reactor Inductor > High Quality Neutral Point Grounding Resistance Resistor Cabinet Cubicle Complete Set Neutral Point Earthing Protection Equipment For Transformer Generator
High Quality Neutral Point Grounding Resistance Resistor Cabinet Cubicle Complete Set Neutral Point Earthing Protection Equipment For Transformer Generator
- 5000 Set / Sets per Month
- Chongqing
- T/T
- 15 days
Product Details
Brand Name: | Enrich Engineering | Place of Origin: | China |
Product Description
Neutral point grounding protection equipment
Neutral point earthing resistance complete set
Small/low current earth-fault line selection device
Includes:1.Transformer neutral point grounding resistance cabinet2.Generator neutral point grounding resistance cabinet3.Low-voltage grounding resistance cabinet4.Transformer neutral point intermittent earth fault protection complete set5.Small current grounding fault line selection device Transformer neutral point grounding resistance cabinet
In a cable-powered system, the grounding capacitor current is large. In order to achieve the impact and requirements on the reliability of equipment operation, equipment insulation and protective measures, the neutral point grounding through the resistor can limit the fault current to a moderate size. On the one hand, the relay protection has sufficient sensitivity and selectivity. At the same time, it can only cause local minor damage to the fault point, limit the transient overvoltage to less than 2.6 times the normal line-to-neutral point voltage, prevent the arc from re-ignition, avoid the arc grounding overvoltage to damage the main equipment and expand the accident. At the same time, the resistance damping has a significant effect on preventing ferromagnetic resonance overvoltage. Generator neutral point grounding resistance cabinet
When a single-phase grounding occurs in the generator circuit of a power plant, and the fault current reaches a certain value, it may cause the occurrence of "intermittent" arc grounding over voltage to have specific "critical" conditions, which cause the generation of arcing grounding over voltage. The withstand voltage level of the generator is weak, and its insulation is easily damaged. If the grounding fault current is too large, the core of the generator will be burnt, and a higher mechanical pressure will be applied to the generator and its circuit.
Therefore, high-resistance grounding is usually used at the neutral point of the generator. When single-phase grounding occurs in its circuit, arc grounding overvoltage is limited to reduce burns to the iron core and reduce mechanical pressure on the generator and its circuits.
Low-voltage grounding resistance cabinetThe low-voltage grounding resistance cabinet is a complete set of resistors for grounding in 0.22KV~0.66KV low-voltage systems. In order to improve the power supply quality of 0.66/0.38/0.22 (KV) low-voltage power systems and reduce equipment outages caused by grounding faults, the low-voltage power system in the main plant of the power plant should use high-resistance grounding, which not only avoids to trip immediately when the phase is grounded not necessary, reduce the probability of burnout when the electrical equipment is running when fuses are used as protective appliances.
After a neutral point grounding resistance cabinet installed, when non-metallic grounding occurs, the current flowing through the grounding point and the neutral point is significantly reduced by the influence of the grounding point resistance, and the non-fault phase voltage rise is also significantly reduced. Zero sequence voltage value is about half that of a single-phase metallic grounding.
Transformer neutral point intermittent earth fault protection complete set
Transformer neutral point intermittent earth fault protection complete set adopts zinc oxide arrester and intermittent parallel operation protection mode, which is suitable for the neutral point of 110KV, 220KV, 330KV power transformers, it not only can protect the transformer neutral point insulation from damaging by lightning overvoltage and power frequency transient overvoltage, but also realize the free switching of two different operation modes of transformer neutral grounding operation or un-grounding operation.Transformer neutral point intermittent earth fault protection complete set (main transformer neutral point grounding combined equipment) is widely used in power plants and power stations such as thermal power, hydropower and wind power, substations of the state grid corporation, coal mining, steel metallurgy, petrochemical and other large industrial and mining enterprises.
Model description
EN-JXB-1/D(S)
EN: Company code
JXB: Transformer neutral point intermittent earth fault protection complete set
1: System voltage
D:Electric mechanism
S:Manual mechanism
EN-JXB-110
EN-JXB-220
EN-JXB-330
Contact Us
- Chongqing Enrich Engineering and Technology Co., Ltd
- Contact nameGuangjian Duan
- Phone86-23-62540401
- power transmission line steel tower
- Electrical equipment frequency converter
- Vector Frequencyinverter
- Overhead power line fault indicator with Three color light display
- short circuit and earth fault indicator distribution system
- Current Temperature And Faults On-line Monitoring instrument
- how to reset overhead line earth fault indicator
- Electric Power Overhead type Cable Fault Indicator
- Simulated Failure Remote Controller for Overhead Line Fault Indicator
- Flag type Overhead type Short circuit &Ground Fault Indicator
- Installation adapter of Overhead Line Fault Indicator
- short circuit and earth fault passage indicator with good price
- overhead Line fault indicator for installation methods and tools
- Flag type Overhead type Short circuit &Ground Fault Indicator
- High Voltage Cable Fault Alarm
- overhead line fault sensor
- SNV-QS High Voltage Live Display Locking Device
- EKL4 Cable Short Circuit and Grounding Fault Indicator
- EKL4 Cable Short Circuit and Grounding Fault Indicator
- Remote Wireless Communication Terminal for overhead grounding and short circuit fault
- medium voltage overhead line fault current sensor and indicator
- Overhead type Short circuit & earth Fault Indicator manufacturer
- earth fault indicator distribution system
- smart sensor for overhead line
Popular Searches
Find Similar Products By Category
- Electrical Equipment & Supplies > Power Distribution Equipment
- Buy on GoldSupplier.com
- How to Buy
- Browse by Catagories
- Browse by Hot Regoins
- Private Sourcing Events
- Sell on GoldSupplier.com
- How to Sell
- Post Products
- Manage Products
- Manage Groups
- About
- About Us
- Link to Us
- Contact Us
- Sitemap
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
Guangjian Duan
Welcome to my shop! Glad to serve you!Please send your question!
Your message has exceeded the limit.
Your message has exceeded the limit.
-
-
Your inquiry content must be between 20 to 5000 characters.Send Now.
-
Please input the mailbox.
-