Home > Products > inverter&converter > Mitsubishi FR-E820-2.2K-1 inverter adopts metal shell and long-life components
Mitsubishi FR-E820-2.2K-1 inverter adopts metal shell and long-life components
- 100000 Unit / Units per Month
- Bao'an international airport
- T/T L/C Credit Card PayPal
- 7 days
- electric ac motor speed controller 480V 32A 18kw 3phase Input&3Phase Output AC frequency converter with 18 months warranty
- 45kw 380v vector control ac frequency converter 50hz 60hz motor frequency inverter 3 phase Power Frequency Converter for Pump
- EM15-G3 General used Vector control Frequency inverter(3 phase )
- EMHEATER soft starter
- EM GS2 7.5KW 220V 240V Motor Soft Starter for Submersible Pump deep well
- Inverter AB PowerFlex®7 Converter 22CD012N103 Inverter PowerFlex 400- 5.5 kW (7.5 HP) AC Drive
Product Details
Brand Name: | Mitsubishi | Place of Origin: | Japan | Model Number: | FR-E820-2.2K-1 |
Type: | DC/AC Inverters | Size: | normal | Weight: | 3.5KG |
Output Power: | 1 - 200KW | Output Type: | Triple | Output Current: | 12.0A |
Output Frequency: | 0.2-590HZ | Output Voltage: | AC200-240Vmax | Input Voltage: | AC200-240V |
Product Description
Common types of Mitsubishi frequency converter
Fr-d700 series
Fr-d700 series frequency converter is a compact multi-function frequency converter.
1. Power range: 0.4~7.5kw;
2. General flux vector control, 150% torque output at 1Hz;
3. Adopt long-life components;
4. Built in Modbus RTU protocol;
5. Built in braking transistor;
6. Expand PID and triangle wave function;
7. With safety stop function.
Fr-e700 series
Fr-e700 series frequency converter is an economical high-performance frequency converter.
1. Power range: 0.1~15kw;
2. Advanced flux vector control, 200% torque output at 0.5Hz;
3. Extended PID, flexible PWM;
4. Built in Modbus RTU protocol;
5. Stop accuracy is improved;
6. Add option card fr-a7nc to support CC link communication;
7. Add option card fr-a7nl to support LonWorks communication;
8. Add option card fr-a7nd, which can support deveice net communication;
9. Add option card fr-a7np to support PROFIBUS DP communication.
Fr-a740 series
1. High precision torque / speed / position control can be carried out in closed loop;
2. Sensorless vector control can realize torque / speed control;
3. Built in PLC function (special model);
4. Use long-life components with built-in EMC filter;
5. Powerful network communication function, supporting DeviceNet, PROFIBUS DP, MODBUS and other protocols.
Fr-f740 series
1. Power range: 37~220kw;
2. Simple magnetic flux vector control mode, achieving output torque of 120% at 3Hz;
3. Better excitation control mode is adopted to realize higher energy-saving operation;
4. Built in PID, frequency converter / power frequency switching and multi pump circulating operation function;
5. Built in RS485 communication port;
6. Use long-life components;
7. Built in noise filter (above 75K);
8. With energy-saving function, the energy-saving effect is clear at a glance.
Adding EMI filter to the input end of Mitsubishi inverter can effectively suppress the conducted interference of Mitsubishi inverter to the power grid. Adding input AC and DC reactors can improve the power factor and reduce harmonic pollution, with good comprehensive effect. When the distance between some motors and Mitsubishi frequency converter exceeds 100 m, it is necessary to add AC output reactor at the side of Mitsubishi frequency converter to solve the leakage current protection caused by the distribution parameters of output wire to the ground and reduce the external radiation interference. An effective method is to adopt the method of threading steel pipe or shielding cable, and reliably connect the steel pipe shell or cable shielding layer with the earth. It is worth noting that when AC output reactor is not added, if steel pipe threading or shielded cable method is adopted, the distributed capacitance of output to ground is increased, and overcurrent is easy to occur. Of course, in practical application, one or several methods are generally adopted.
Control cabinet: Mitsubishi Inverter should be installed inside the control cabinet. The following problems should be paid attention to in the design of the control cabinet. 1. Heat dissipation of Mitsubishi inverter: the heating of Mitsubishi inverter is caused by internal losses. The main circuit is the main part of the losses in Mitsubishi frequency converter, accounting for about 98%, and the control circuit accounts for 2%. In order to ensure the normal and reliable operation of Mitsubishi inverter, it is necessary to heat the Mitsubishi inverter. We usually use fans for heat dissipation; The built-in fan of Mitsubishi frequency converter can take away the heat dissipation inside the box of Mitsubishi frequency converter. If the fan cannot work normally, stop the operation of Mitsubishi frequency converter immediately; The high-power Mitsubishi inverter also needs to add a fan to the control cabinet. The air duct of the control cabinet should be designed reasonably. All air inlets should be equipped with dust screens to ensure smooth exhaust, so as to avoid eddy currents in the cabinet and dust accumulation at fixed positions; The matching fan shall be selected according to the ventilation volume in the manual of Mitsubishi inverter, and attention shall be paid to the shockproof problem in the installation of the fan.
Ambient temperature of Mitsubishi inverter: when the temperature is too high and the temperature changes greatly, the internal of Mitsubishi inverter is prone to condensation, and its insulation performance will be greatly reduced, which may even cause short circuit accidents. If necessary, desiccant and heater must be added to the tank. In the water treatment room, the water vapor is generally heavy. If the temperature changes greatly, this problem will be more prominent.
At present, the A700 series and e700 series of Mitsubishi inverter are widely used in the market. A700 series is a general-purpose inverter, which is suitable for occasions with high starting torque and high dynamic response. The e700 series is suitable for occasions with simple functional requirements and low requirements for dynamic performance, and has advantages in price.
Electromagnetic wave interference: due to rectification and frequency conversion during the operation of Mitsubishi frequency converter, a lot of interference electromagnetic waves are generated around. These high-frequency electromagnetic waves have certain interference on nearby instruments and instruments. Therefore, the instrument and electronic system in the cabinet should use metal shell to shield the interference of Mitsubishi inverter to the instrument. All components and parts shall be reliably grounded. In addition, shielded control cables shall be selected for the wiring between electrical components, instruments and meters, and the shielding layer shall be grounded. If electromagnetic interference is not handled properly, the whole system will often fail to work, resulting in control unit failure or damage.
Contact Us
- Huizhou Linchuang Technology Co ., Ltd
motor part | motor | filter | other electric equipment |
drives | controller | power supply | inverter&converter |
contactor | amplifier | radiator | resistor |
circuit-breake |
- EMHEATER 250kw Three 3 phase 380V 400v 440V Input Motor Soft Starter for Submersible Pump Compressor
- 45kw 440v three phase star delta motor on line starter with bypass built in
- Economical Soft Starter 90kw Electric Motor Controller 3 Phase 400v 380v Motor Soft Starter 50Hz to 60Hz for motor protection
- Low Price 380V/480V 30KW Solid State Motor Starters Low Voltage Soft Starters with 60A Triple Output for Motor Protection
- MITSUBISHI HC-SF102BK (AS PICTURED) NSNP
- MITSUBISHI HC-SFS152 SERVO MOTOR
- original Mitsubishi MITSUBISHI HC202S NSNP
- AB 2711R-T7T
- AB 1492 1494 1497
- AB soft starter 150 153 156
- 480V 600KW 1200A 3 phase online working soft starter for AC motor pump mill motor air compressor no need bypass contactor
- 460V 480V 600KW 3 phase output power motor soft starter for Zimbabwe market AC motors
- 380V 500KW 1000A 3 phase input &output Soft starter for industrial pump acmotor air gas compressor fan crusher drawing machine
- 380V 500KW 1000A 3phase online working soft starter for AC motor pump mill motor air compressor no need bypass contactor
- 380v 500kw 3Phase input and output Frequency Converter Inverter speed drive Industrial ControL
- 480V 500KW 440V 3 phase Online Working Soft Starter VSD for AC motor pump mill motor air compressor no need bypass contactor
- 380V 500KW 1000A 3 phase input&output sine wave filter for variable frequency drive soft starters AC electric motor
- 380V 500KW Motor Controller Soft Starters for 3-phase Induction Motors Protection Relay
- TOP1 Hot Sales MPPT Solar Water Pump Inverter 3 Phase Triple Output DC/AC Inverter
- DC to AC 3-Phase 380V/220V MPPT Solar Water Pump Inverter/VFD with Variable Frequency and Triple Output Type
- 380V 450KW 900A 3 phase online working soft starter for AC motor pump fan mill motor air compressor no need bypass contactor
- 380V 600KW 800HP 3phase online working soft starter for AC motor pump motor compressor fan colloid mill built-in bypass
- China made Inverter AAD03020DKT01 for power plant
- Allen Bradley Soft Starter AB 150-F480NZD
Popular Searches
Find Similar Products By Category
- Electrical Equipment & Supplies > Power Supplies > Inverters & Converters
- Buy on GoldSupplier.com
- How to Buy
- Browse by Catagories
- Browse by Hot Regoins
- Private Sourcing Events
- Sell on GoldSupplier.com
- How to Sell
- Post Products
- Manage Products
- Manage Groups
- About
- About Us
- Link to Us
- Contact Us
- Sitemap
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
sales
Welcome to my shop! Glad to serve you!Please send your question!
Your message has exceeded the limit.
Your message has exceeded the limit.
-
-
Your inquiry content must be between 20 to 5000 characters.Send Now.
-
Please input the mailbox.
-