Home > Products > surface area and porosimetry analyzers > V-Sorb 4800 BET surface area and pore volume analyzer
V-Sorb 4800 BET surface area and pore volume analyzer
- 30 Set / Sets per Month
- Shanghai
- T/T L/C D/P D/A Credit Card PayPal Cash Escrow Other
- 1 days
- V-Sorb 4800P surface area and pore size analyzer
- V-Sorb 4800S specific surface area analyzer
- V-Sorb 4800TP surface area and porosimetry analyzer
- H-Sorb 2600PCT hydrogen adsorption isotherms determination analyzer
- H-Sorb 2600PCT H2 adsorption PCT isotherms determination analyzer
- H-Sorb 2600PCT H2 adsorption PCI isotherms determination analyzer
Product Details
Brand Name: | Gold APP Instruments | Place of Origin: | China | Model Number: | V-Sorb 4800 |
Product Description
V-Sorb 4800 BET surface area and pore volume analyzer introduction
V-Sorb 4800 BET surface area and pore volume analyzer is researched by Gold APP Instruments for surface area and pore size testing by utilizing static volumetric principle. It can be used for those materials which pore size is limited to mesopore (2-50nm), of course plus the surface area data determination too. High cost performance and high through-put of V-Sorb 4800 BET surface area and pore volume analyzer easily meet your demands no matter in research or quality control.
V-Sorb 4800 BET surface area and pore volume analyzer specifications
1. Analysis Principle: volumetric nitrogen adsorption.
2. Analysis Data: adsorption/ desorption isotherms, BET (Brunauer-Emmett-Teller) surface area, Langmuir surface area, t-plot surface area, BJH (Barrett-Joyner-Halenda) pore size distribution, pore volume analysis.
3. Measuring Ranges: 0.01 m2/g (by nitrogen)/ 0.0005m2/g (by krypton) to no known upper limit (specific surface area); 2 to 500nm (pore size).
4. Accuracy: repeatability errors ≤1%.
5. Coolant Level Prober: V-Sorb original coolant level probe system with temperature probe.
6. Sample Degassing: the whole degassing be controlled by software, as well with a start time preset function which can realize unattended operation at night.
7. Sample Stations: 4 testing and 4 degassing concurrently.
8. Pressure Transducer: imported silicon thin film pressure transducer, accuracy can reach 0.1% of real reading, better than 0.1% of F.S.(full-scale). P/Po controllable accuracy range is 5x10-6-0.998
9. Ultimate Vacuum: 4x10-2Pa (3x10-4Torr)
10. Data Reduction: Windows based software, perfect versatility, produced full featured and multi-model reports
V-Sorb 4800 BET surface area and pore volume analyzer technical features
1. Unique integral manifolds system, decrease connecting points apparently, reduce leak rate, improve ultimate vacuum.
2. Brand vacuum pump, low noise, stable working, oil-return prevention; ultimate vacuum can reach 4x10-2Pa (3x10-4Torr).
3. Separated analysis and degassing manifolds can prevent foreign matter to contaminate analysis manifolds.
4. Original stepping coolant level control system, ensure the coolant level unchanged when compares with sample cells in the whole analysis process, completely eliminate the analysis errors caused by dead volume
5. High precision and integration data acquisition module is easy to connect, minimal errors and strong anti-interference ability; the standard 485 communication mode benefits analyzer upgrade and interconnection, also can be conveniently switched to RS232 or USB modes.
Our policy of continuous development may cause the information and specifications contained herein to change without notice or liability.
Contact Us
- Gold APP Instruments Corporation Limited
- Contact nameAndy
BET surface area analyzers | surface area and porosimetry analyzers | helium true density analyzer | high pressure volumetric adsorption analyzer |
hydrogen adsorption analyzer |
- H-Sorb 2600PCT H2 adsorption TPD isotherms determination analyzer
- G-DenPyc 2900 True Density & Helium Pycnometry Analyzer
- G-DenPyc 2900 Gas (Helium) Pycnometer Theory and Practice
- G-DenPyc 2900 density measurement with a helium pycnometer
- G-DenPyc 2900 porosity determination with helium pycnometry
- G-DenPyc 2900 Gas Pycnometer and Helium Pycnometers
- G-DenPyc 2900 Gas Pycnometer for Semi-Solid and Solid Density
- G-DenPyc 2900 Professional Gas Pycnometer
- G-DenPyc 2900 Air and Helium Pycnometer
- G-DenPyc 2900 Fully Automated Gas Pycnometer
- G-DenPyc 2900 Analytical Grade Pycnometer
- H-Sorb 2600 Hydrogen Storage Analyzer
- H-Sorb 2600 High Temperature Hydrogen Storage Gas Adsorption Analyzer
- H-Sorb 2600PCT High Pressure Gas Adsorption Analyzers
- H-Sorb 2600PCT Hydrogen Storage Materials and Sorption Analysis Equipment
- H-Sorb 2600PCT High Temperature Hydrogen Storage Gas Adsorption
- H-Sorb 2600PCT High Temperature Hydrogen Storage Gas Adsorption Analyzer
- H-Sorb 2602PCT Automatic High-pressure Gas Adsorption Analyzer
- F-Sorb 2400CE Single-Point and Multi-Point Surface Area Measurements
- F-Sorb 2400CE the single point BET method
- F-Sorb 2400CE Brunauer-Emmett-Teller (BET) surface area analysis
- F-Sorb 2400CE BET Surface Area Analysis of Nanoparticles
- F-Sorb 2400CE BET Specific Surface Area Testing
- F-Sorb 2400CE BET Method for Determining Surface Areas
Popular Searches
Find Similar Products By Category
- Measurement & Analysis Instruments > Measuring & Analysing Instrument Stocks
- Buy on GoldSupplier.com
- How to Buy
- Browse by Catagories
- Browse by Hot Regoins
- Private Sourcing Events
- Sell on GoldSupplier.com
- How to Sell
- Post Products
- Manage Products
- Manage Groups
- About
- About Us
- Link to Us
- Contact Us
- Sitemap
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
Andy
Welcome to my shop! Glad to serve you!Please send your question!
Your message has exceeded the limit.
Your message has exceeded the limit.
-
-
Your inquiry content must be between 20 to 5000 characters.Send Now.
-
Please input the mailbox.
-