Home > Products > surface area and porosimetry analyzers > V-Sorb 4800TP surface area and porosimetry analyzer
V-Sorb 4800TP surface area and porosimetry analyzer
- 30 Set / Sets per Month
- Shanghai
- T/T L/C D/P D/A Credit Card PayPal Cash Escrow Other
- 1 days
- H-Sorb 2600PCT hydrogen adsorption isotherms determination analyzer
- H-Sorb 2600PCT H2 adsorption PCT isotherms determination analyzer
- H-Sorb 2600PCT H2 adsorption PCI isotherms determination analyzer
- H-Sorb 2600PCT H2 adsorption TPD isotherms determination analyzer
- G-DenPyc 2900 True Density & Helium Pycnometry Analyzer
- G-DenPyc 2900 Gas (Helium) Pycnometer Theory and Practice
Product Details
Brand Name: | Gold APP Instruments | Place of Origin: | China | Model Number: | V-Sorb 4800TP |
Product Description
V-Sorb 4800TP surface area and porosimetry analyzer introduction
V-Sorb 4800TP surface area and porosimetry analyzer, the top grade model among surface our physisorption analyzer, is researched by Gold APP Instruments engineers for surface area, mesopore, micropore and ultra micropore determination.
It equipped with our multi pioneered technologies these make its performance much better, heighten accuracy and consistence of results, and enhance measurement stability, all these lead to a leading one among global competitors. V-Sorb 4800TP surface area and porosimetry analyzer has a turbo pump and 0.1 torr pressure transducer, ideally suited for gas adsorption analysis of microporous and mesoporous materials and delivers superior accuracy, resolution and data reduction.
V-Sorb 4800TP surface area and porosimetry analyzer application fields
1. Ultra microporous, mesoporous materials as metal organic frameworks (MOFs), organic polymers, zeolite design, carbon adsorbents, catalyst performance etc. research.
2. Research institutes, universities for BET (Brunauer-Emmett-Teller) theory teaching.
3. Other researches concern specific surface area and pore size performance like pharmaceuticals, ceramics, adsorbents, activated carbon, projectile propellant, medical implants, electronics, cosmetics, aerospace, nanotube etc. many industry fields.
V-Sorb 4800TP surface area and porosimetry analyzer specifications
1. Analysis Method: static volumetric nitrogen adsorption principle
2. Data Analysis: isotherms, BET, Langmuir, t-plot surface area, BJH, t-plot, MP, HK, SF, DR, DA etc. mesopore and micropore.
3. Vacuum System: V-Sorb unique stainless steel micro welding vacuum manifolds system, metal-to-metal (VCR) fittings; the VCR metal fittings’ vacuum leak rate can reach 1x10-10 (Pa*m3/s).
4. Vacuum Manifolds: V-Sorb unique monolithic manifolds and pneumatic valve control system, greatly reduce the dead volume.
5. Measuring Ranges: 0.01 m2/g (by nitrogen)/ 0.0005m2/g (by krypton) to no known upper limit (specific surface area); 0.35 to 500nm (pore size)
6. Accuracy: repeatability errors ≤1%
7. Data Acquisition: high-precision and high integration data acquisition and archiving system, minimal error, strong anti-interference ability.
8. Sample Ports: 4 analyzing and 4 degassing ports.
9. Control System: programmable pneumatic valve system with high integration and strong anti-interference ability, ensure instrument stability and working life.
10. Pressure Measurement: sectional measurement pressure transducers, 1000Torr, 1Torr and 0.1Torr three transducers are equipped. Accuracy can reach 0.1% of real reading, better than 0.1% of F.S. (full-scale).
11. Vacuum Pump: built-in 1 mechanical pump plus 1 turbo pump, all be fully controlled by software.
12. Dewar: branded 4 liter stainless steel Dewar can provide at least 72 hours of unattended measurement without refilling the LN2.
13. Ultimate Vacuum: mechanical pump: 4x10-2 Pa (3x10-4 Torr), molecular pump: 5x10-8 mbar
V-Sorb 4800TP surface area and porosimetry analyzer technical features
1. Stainless steel micro welding vacuum manifolds system can reduce the leak rate apparently, improve ultra-vacuum value, without need daily maintenance.
2. Branded turbo molecular pump, ultimate vacuum can reach 5x10-8-0.998, maintenance free, easy to use.
3. Imported high vacuum pneumatic valve sealing performance is up to 5x10-12 (Pa﹡ m3/s), can completely remove temperature change be caused by valves heating.
4. Fully metal-to-metal VCR connecting can eliminate gas leak problem under high vacuuming, efficiently improve ultimate vacuum and analysis reliability.
5. Imported high-precision silicon thin film pressure transducer, can be auto controlled by software; the 0.1 Torr full-scale transducer assists micropore to achieve a more accuracy data for low P/Po points.
6. Programmable pneumatic valve system with high integration and strong anti-interference ability, speed and easy for upgrade and maintenance.
7. Fully automatic operation and modularity design, equips with dedicated software, can realize unattended operation at night.
8. Multi calculating formulas for data reduction provides all-round sample analysis options; powerful data archiving and searching system helps a lot for data management.
Our policy of continuous development may cause the information and specifications contained herein to change without notice or liability.
Contact Us
- Gold APP Instruments Corporation Limited
- Contact nameAndy
BET surface area analyzers | surface area and porosimetry analyzers | helium true density analyzer | high pressure volumetric adsorption analyzer |
hydrogen adsorption analyzer |
- G-DenPyc 2900 density measurement with a helium pycnometer
- G-DenPyc 2900 porosity determination with helium pycnometry
- G-DenPyc 2900 Gas Pycnometer and Helium Pycnometers
- G-DenPyc 2900 Gas Pycnometer for Semi-Solid and Solid Density
- G-DenPyc 2900 Professional Gas Pycnometer
- G-DenPyc 2900 Air and Helium Pycnometer
- G-DenPyc 2900 Fully Automated Gas Pycnometer
- G-DenPyc 2900 Analytical Grade Pycnometer
- H-Sorb 2600 Hydrogen Storage Analyzer
- H-Sorb 2600 High Temperature Hydrogen Storage Gas Adsorption Analyzer
- H-Sorb 2600PCT High Pressure Gas Adsorption Analyzers
- H-Sorb 2600PCT Hydrogen Storage Materials and Sorption Analysis Equipment
- H-Sorb 2600PCT High Temperature Hydrogen Storage Gas Adsorption
- H-Sorb 2600PCT High Temperature Hydrogen Storage Gas Adsorption Analyzer
- H-Sorb 2602PCT Automatic High-pressure Gas Adsorption Analyzer
- F-Sorb 2400CE Single-Point and Multi-Point Surface Area Measurements
- F-Sorb 2400CE the single point BET method
- F-Sorb 2400CE Brunauer-Emmett-Teller (BET) surface area analysis
- F-Sorb 2400CE BET Surface Area Analysis of Nanoparticles
- F-Sorb 2400CE BET Specific Surface Area Testing
- F-Sorb 2400CE BET Method for Determining Surface Areas
- F-Sorb 2400CE Surface Area: Brunauer–Emmett–Teller (BET)
- V-Sorb 4800P BET Surface Area Analysis & BJH Pore Size & Volume
- V-Sorb 4800S specific surface area analyzer
Popular Searches
Find Similar Products By Category
- Measurement & Analysis Instruments > Measuring & Analysing Instrument Stocks
- Buy on GoldSupplier.com
- How to Buy
- Browse by Catagories
- Browse by Hot Regoins
- Private Sourcing Events
- Sell on GoldSupplier.com
- How to Sell
- Post Products
- Manage Products
- Manage Groups
- About
- About Us
- Link to Us
- Contact Us
- Sitemap
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
Andy
Welcome to my shop! Glad to serve you!Please send your question!
Your message has exceeded the limit.
Your message has exceeded the limit.
-
-
Your inquiry content must be between 20 to 5000 characters.Send Now.
-
Please input the mailbox.
-