BKS 666KVAR 33KV Oil immerse Shunt Reactor
- USD $600 - $1500 / Piece |Get Latest Price
- 1 Piece / Pieces
- 2000 Piece / Pieces per Month
- Shanghai
- T/T L/C
-
110Kv-220kv Oxide Lighten Arrester
-
FN7-12DR AC high-voltage load switch
-
10kV voltage regulating Distribution Transformer
-
ZW32-12 Series outdoor Pole mounted high voltage vacuum circuit breaker
-
DC surge Protection for solar system
-
1200V DC surge Protection for solar system /photovoltaic power supply system
Product Description
BKS oil-immerse shunt reactor is used to compensate the capacitive charging current of the line, limit the rise of the system power frequency voltage and the operating overvoltage, thus reducing the insulation level of the system and ensuring the reliable operation of the line. With the continuous expansion of China's urban scale and the transformation of the urban power grid, the overhead line transmission is gradually replaced by the underground cable transmission, making the capacitive charging current to the ground of the transmission network increase sharply. In order to reduce the rise of the system power frequency voltage and the system insulation level, ensure the safe and reliable operation of the system and the quality of the urban power grid power supply Shunt reactors widely used in long-distance transmission systems are widely used in urban distribution networks.
Working conditions
1. Altitude shall not exceed 1000 meters;
2. Operating ambient temperature is - 25 ℃ to+45 ℃, and the relative humidity is not more than 90%;
3. No harmful gas, flammable and explosive substances around.
Performance parameters
Rated voltage: 10kV, 35kV
Insulation level: Li75AC35, Li200AC85
Rated frequency: 50Hz
Insulation class: Class A
Connection group: Y
Rated reactance rate: 100%
Executive standards
GB 1094.1-1996 Power Transformers Part 1 General
GB 1094.2-1996 Power Transformers - Part 2: Temperature Rise
GB 1094.3-2003 Power Transformers - Part 3: Insulation Level Insulation Test and External Insulation Air Gap
GB 1094.5-2003 Power Transformers - Part 5: Ability to withstand short circuit
JB/T5346-1998 Series Reactor
GB/T10229-1988 Reactor
DL/T462-1992 Technical Conditions for Ordering Series Reactors for High Voltage Shunt Capacitors
IEC289-1988 Reactor
Technical Data
Model | Rated Capacity(Kvar) | System Voltage kV | Rated Current A | Rated ReactanceΩ | Oil Weight(kg) | Total Weight (kg) | Dimension mm(L*W*H) | Installation Dimension mm (A×B) |
BKS-72/10 | 72 | 10.5 | 3.96 | 1530.9 | 60 | 320 | 710×510×940 | 450×600 |
BKS-114/10 | 114 | 10.5 | 6.27 | 966.85 | 97 | 420 | 780×610×1110 | 450×600 |
BKS-144/10 | 144 | 10.5 | 7.92 | 765.4 | 120 | 660 | 890×710×1210 | 650×710 |
BKS-300/10 | 300 | 10.5 | 16.5 | 367.4 | 140 | 790 | 1220×750×1310 | 670×710 |
BKS-600/10 | 600 | 10.5 | 33 | 183.8 | 560 | 2250 | 1430×910×1640 | 820×850 |
BKS-1200/10 | 1200 | 10.5 | 65.98 | 91.88 | 710 | 2690 | 1710×1010×1670 | 910×950 |
BKS-3000/10 | 3000 | 10.5 | 164.96 | 36.75 | 1300 | 4200 | 2100×1710×1800 | 1200×1120 |
BKS-8000/10 | 8000 | 10.5 | 439.9 | 13.78 | 3200 | 8150 | 2700×2230×2700 | 1650×1475 |
BKS-10000/10 | 10000 | 10.5 | 549.86 | 11.02 | 4200 | 13200 | 3000×2400×3100 | 2×1160×1700 |
BKS-5000/35 | 5000 | 38.5 | 74.98 | 296.45 | 3800 | 11500 | 2700×2300×3300 | 2×1120×1510 |
BKS-8000/35 | 8000 | 38.5 | 119.97 | 185.28 | 4500 | 15100 | 3100×2400×3500 | 2×1160×1900 |
BKS-10000/35 | 10000 | 38.5 | 149.96 | 148.23 | 4900 | 17100 | 3400×2900×3500 | 2×1270×2010 |
BKS-20000/35 | 20000 | 38.5 | 299.92 | 74.11 | 7850 | 27500 | 4100×3100×4200 | 2×1550×2210 |
Contact Us
- Yueqing Debo International Trading Co.,Ltd
- ContactVicky Huang
- Phone86-577-62071980
- AddressYueqing Wenzhou,Zhejiang
Capacitor | semiconductor device | fuse | Reactor |
High voltage Disconnector switch | Discharge Coil | Vacuum Circuit Breaker | Oxide Surge Arresters |
Transformer | Vacuum Load Switches | DC surge protection |
-
Photovoltaic special Surge protective for lightning protector
-
YSG three-phase Dry-type servo transformer
-
6-10kV series of metal oxide Surge arresters
-
Hot sale 6Kv Oxide Lighten Arrester
-
110Kv substation type Oxide Lighten Arrester
-
110Kv substation type Oxide Lighten Arrester
-
110Kv-220kv Oxide Lighten Arrester
-
BSMJ self-healing low voltage shunt capacitor
-
35KV Differential Voltage Dry type Discharge coil
-
ZW7-40.5Series outdoor high voltage vacuum circuit breakers
-
ZW32-24 Series outdoor pole mounted high voltage vacuum circuit breaker
-
ZW32-12 Series outdoor Pole mounted high voltage vacuum circuit breaker
-
FKN12-27.5 D bipolar Load switch
-
DC fliter reactor
-
SC (B) 10 type 10kV resin insulated dry-type power transformer
-
CKS oil-immerse Series reactor
-
BKS Oil immerse Shunt Reactor China supplier
-
10kV voltage regulating Distribution Transformer
-
S11 type 10kV non-excitation voltage regulating distribution transformer
-
QSKC HV Starting Reactor - Iron core reactor
-
FDGE series 10KV Dry type Discharge coil for power grid
-
24kv Handcart type Vacuum Circuit Breaker indoor
-
FN7-12DR AC high-voltage load switch
-
12KV indoor HV rotation disconnecting switches
Popular Searches
- autoclave reactor
- bed reactors
- chemical reactor
- chlor alkali
- continuous stirred tank reactor
- fixed bed reactor
- fluidized bed reactor
- glass chemical reactor
- glass lined reactor
- glass reactor
- high pressure chemical reactor
- high pressure glass reactor
- jacketed glass reactor
- reaction kettle
- microwave reactor
- stainless steel reactor
Find Similar Products By Category
- Machinery > Chemical & Pharmaceutical Machinery > Chemical Machinery & Equipment > Reactors
- Hot Searches:
- HV series reactor
- High voltage reactor
- Dry type reactor