Home > Products > Lab Equipment > ATP Swabs
ATP Swabs
- Negotiable |Get Latest Price
- 1 Piece / Pieces
- 1000 Piece / Pieces per Month
Product Details
Brand Name: | ECALBIO |
Product Description
Put the swab under refrigerated condition at room temperature for about 10 minutes, boot up, wait for its self inspection end.
Hold the sealing tube with one hand tightly as shown in Fig 2 pull out the sealing tube with the other hand lightly (Do not pull the sealing tube directly! ).
With cotton head sampling. wipe the object surface evenly. side rolling edge wipe with Z shape, wipe area of about 100cm, or soak it all in the liquid to be tested and then take it out quickly. After the sampling is completed, the sealing tube sleeve is attached.(The broken swab must be put into the instrument within 10 seconds.)
Put the swabs into the ATP fluorescence detector quickly, press the OK key, and read the number in 15 seconds.
Principle
ATP swabs is fluorescence detection using ATP detector.
Content
Sealing tube CAP
Swab COTTON
Sealing tube TIP
Detect process:
Specification:
Type | Product No | Compatible ATP luminometers | RLU (100 fmol ATP) | RLU Stability after 15s | Other ATP tests with equal RLU |
Water Test | Ecalbio W1 | Hygiena Ensure | 880 | 71% | Hygiena AquaSnap |
Hygiena Plus | 440 | ||||
Ecalbio 1 (economical mode) | 400 | ||||
Ecalbio W2 | Hygiena Ensure | 210 | 94% | ||
Hygiena Plus | 105 | ||||
Ecalbio 1 (economical mode) | 90 | ||||
Ecalbio W3 | 3M Clean Trace | 1212 | 96% | 3M Clean Trace | |
Surface Test | Ecalbio S1 | Hygiena Ensure | 880 | 71% | Hygiena SuperSnap |
Hygiena Plus | 440 | ||||
Ecalbio 1 (economical mode) | 380 | ||||
Ecalbio S2 | Hygiena Ensure | 202 | 94% | Hygiena UltraSnap | |
Hygiena Plus | 102 | ||||
Ecalbio 1 (economical mode) | 90 | ||||
Ecalbio S3 | 3M Clean Trace | 1128 | 98% | 3M Clean Trace |
Note:
RLU (100fmol ATP) is tested by collecting 100 μl of 1 x 10-9 M ATP solution in the case of the water tests, and adding 10μl of 1 x 10-8 M ATP solution onto the swab in the surface tests. The tests are done at room temperature.
RLU stability after 15s means the percentage of the second RLU read by the meters over the first RLU read. The time interval between the second read and the first read is 15 s.
Shelf life:
All the test kits are stable for 15 months keeping at 2-8℃.
Package:
100 pcs/bag.
Web:
Address: HZAU, Nanhu Road, Wuhan city 430075, China.
Tel: +86 27 87745856
Fax: +86 27 87745856
E-mail: info@ecalbio.com
Contact Us
- ECALBIO CO.,LTD
Antibody | Antibody biosimilar | Chemical Materials | Food Safety ELISA Kit |
ELISA Kit | Lab Equipment |
-
Bird's Nest qPCR Test Kit
-
Cubilose qPCR Test Kit
-
HRP Labeling kit
-
SYBR Solution/SYBR Premix Ex Taq Kit
-
HRP Labeling kit
-
CD63 aptamer
-
Smart Silencer-lncRNA/mRNA
-
Single Gene siRNA Set
-
FISH & ChIRP Probe
-
One-Step TUNEL Apoptosis Detection
-
miRNA mimics & inhibitors
-
Exosomes Extraction Reagent
Popular Searches
Find Similar Products By Category
- Chemicals > Lab Supplies > Other Lab Supplies