Home > Products > marine centrifugal fan > CBGD series marine explosion-proof high efficiency low noise centrifugal fans
CBGD series marine explosion-proof high efficiency low noise centrifugal fans
- 10000 Piece / Pieces per Month
- QINGDAO/SHANGHAI/TIANJIN/GUANGZHOU and so on
- T/T L/C D/P D/A Credit Card PayPal Cash Other
- 10 days
Product Details
Brand Name: | YAOSEN | Place of Origin: | China | Model Number: | CBGD-20-2——CBGD-80-6 |
Certification: | Other, CCS/BV/LR/VR/KR and so on | After-sales Service Provided: | Overseas service center available | Voltage: | 220/380/440 V |
Power: | 0.55——15 KW | Speed: | 3500/2920/1750/1460/1160/970 r/min | Air Volume: | 400——19000 m³/h |
Blade Material: | Other, aluminum | Mounting: | Other, marine fan | Electric Current Type: | AC |
Product Description
1. General
TYPE CBGD marine explosion-proof or high efficiency low noise centrifugal fans are explosion-proof products for marine use which developed from the CGDL series marine centrifugal fans. The series are designed and manufactured according to Marine explosion-proof fans,Electrical apparatus for explosive atmospheres and ship regulations of Chinese and international.Non-sparking fans are suitable for every cabin air ventilating and exchanging on ships which containing combustible and explosive gas. They are also applicable in other places that suit.This series fans have been examined and proved up to standard by the Explosion-proof inspection Authority of the PRC and have got the certificate of inspection. They have also been examined by the Register of Shipping of PRC and have got the certificate.
2. Features
This series, non-sparking fans have the features of high explosion-proof grade, high efficiency, low noise, no overload, well anticorrosive, resistance to swing vibration and shock, stable turning and safely, reliability, etc.
3. Structure
There are two structural types:Type I (direct-coupling type) and type II (separate cabins type). The construction is non-sparking. The structure of type I is a motor direct coupling one, the impeller is mounted directly on the motor shaft, and the casing is fixed on the flange of the explosion-proof motor.
The type II is a separate structure, the fan and the motor are put into different cabins, with a driving device, flexible couplings, and the driving device and the other side will be mounted on the bulkhead.consists of bearings, bearing-box, shaft, brass rings, stuffing box, it can be oiled and measured the temperature. One side is fixed on the fan, The fan may be made into a horizontal or vertical, single-stage, single-drawing and airtight structure by the customer’s requirement.
4. Model Explanation
5. Use and maintenance
5.1 Before installing the fans, should check whether each part is intact, whether the components are complete, whether the impeller and casing rotating direct are concordant.5.2The air enter the fan from axial direction and come out through the impeller. It can be used for left or right rotation.5.3When installing the duct of the inlet and outlet, should make the duct and fans be spontaneous identical, not join them forcing, not bring the weight of duct on the fans.5.4After installed the fans, check whether there is friction of collide between the impeller and the fixed parts by rotating the impeller. If collision, friction, loud noise or strong vibration happened, the fan should be restart after checking. Avoid the fan being bumped and other substance or liquid entered the fans. Please clean the dust on blade of impeller in time, so as not to break the balance and strengthen the noise.5.5The fans should be start-up without load. Before the fans started, should close the inlet or the adjust fittings. After operating, start to turn on it until to the formulary work state. 5.6The impeller’s rotating direct and the direct of the arrow should be concordant.5.7After the fans wiring, the terminal box should be sealed, avoid the air or water in it.5.8As the fans operating, the motor electric current should be control strictly, not exceed the rated electric current. Avoid the motor burning, 5.9The fans maintain must be done on stop working time. When burning, after check, should whether the every part of fans is normal.5.10As some fault occurred in fans operating, should find out the reason in time and think a way of resolution.
Please contact us and get detailed Technical parameters and Drawings.
We could Design and Produce the Marine fan,Industrial Fan,and Other Ventilation Equipment according to your detailed requirement !
Contact Us
- QINGDAO YAOSEN MARINE EQUIPMENT CO.,LTD
marine axial flow fan | marine centrifugal fan | marine mushroom head | marine explosion-proof fan |
Motor,Impeller &Accessory | marine duct fan |
- B-TYPE Marine mushroom air vent head
- C-TYPE Marine mushroom air vent head
- D-TYPE Marine mushroom air vent head
- E-TYPE Marine mushroom air vent head
- CBZ-V Series Marine Explosion-proof Axial Fan
- JCZ-20 marine axial flow fan for bathroom
- JCZ-25 marine axial flow blower for cargo hold
- JCZ-30A marine axial flow fan for engine room
- JCZ-30B marine axial flow blower for cargo hold
- JCZ-35A axial flow ventilator for the deck of ship
- JCZ-35B marine exhaust fan
- JCZ-40A Marine axial flow ventilation fan
Popular Searches
Find Similar Products By Category
- Machinery > General Industrial Equipment > Ventilation Fans > Centrifugal Fans
- Buy on GoldSupplier.com
- How to Buy
- Browse by Catagories
- Browse by Hot Regoins
- Private Sourcing Events
- Sell on GoldSupplier.com
- How to Sell
- Post Products
- Manage Products
- Manage Groups
- About
- About Us
- Link to Us
- Contact Us
- Sitemap
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
sales
Welcome to my shop! Glad to serve you!Please send your question!
Your message has exceeded the limit.
Your message has exceeded the limit.
-
-
Your inquiry content must be between 20 to 5000 characters.Send Now.
-
Please input the mailbox.
-